Chapter 12 — Installing the circuit cards
Trunk Data Block
Use Overlay 14 to configure each of the trunk units on the NTCK18AA cen-
tral office trunk.
LD 14 - Trunk Data Block
Prompt
Response
REQ
NEW
TYPE
COT
TN
CC UU
XTRK
XCOT
see note 1
CDEN
(8D)
SIGL
LOP
PPID
04
see note 1
BTID
12
see note 1 & 2
13
BIMP
(600), 3COM
SEIZ
YES, (NO)
CLS
SHL, (LOL)
BTS, (XBTD)
DTN, (DIP)
Note 1: These prompts are required only for the first unit defined on
each NTCK18AA card.
Note 2: BTID = 12, corresponds to busy tone cadence of 200 ms on /
200 ms off.
BTID = 13 corresponds to busy tone cadence of 500ms on / 500ms off.
Comments
Define a new trunk unit
Central Office Trunk
Terminal number of the unit in Option
11 format:
CC=card number
UU=unit number
Type is IPE COT
Card density is 8D (default)
Loop start signaling
Italian PPM ID
Italian Busy Tone ID
Balance impedance selection
Automatic guard detection for outgoing
trunk
Attenuation Pads In, (Out)
Busy tone supervision enabled,
(disabled)
Digitone signaling, (digipulse)
Option 11C Mini
Planning and Installation Guide