Set Normal Mode; Set Expert Mode - HIKVISION DS-2TD4238-7/S2 User Manual

Thermal & optical bi-spectrum ptz network camera
Hide thumbs Also See for DS-2TD4238-7/S2:
Table of Contents

Advertisement

Thermal & Optical Bi-spectrum PTZ Network Camera User Manual

3.3.2 Set Normal Mode

This function is used to measure the temperature of the whole scene and alarm.
Steps
1. Go to Configuration → Temperature Measurement → Basic Settings , and check Enable
Temperature Measurement.
2. Refer to Set Thermography Parameters to set the parameters.
3. Go to Configuration → Temperature Measurement → Advanced Settings , and select Normal.
4. Configure the parameters of normal mode.
Emissivity
Set the emissivity of your target. The emissivity of each object is different.
Distance
The distance between the target and the device.
Pre-Alarm Threshold
When the temperature of target exceeds the pre-alarm threshold, and this status keeps more
than Filtering Time, it triggers pre-alarm.
Alarm Threshold
When the temperature of target exceeds the alarm threshold, and this status keeps more
than Filtering Time, it triggers alarm.
Pre-Alarm Output and Alarm Output
Check Pre-Alarm Output and Alarm Output to link the pre-alarm or alarm with the
connected alarm device.
5. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for
setting linkage method.
6. Click Save.
The maximum and minimum temperature will be displayed on the live view.
Note
Go to Image → VCA Rules Display to adjust the font size and the temperature color of normal,
alarm and pre-alarm.

3.3.3 Set Expert Mode

Select the temperature measurement rules from Point, Line, or Area and configure parameters,
the device alarms if the alarm rules are met.
Steps
1. Go to Configuration → Temperature Measurement → Basic Settings , check Enable
Temperature Measurement.
9

Advertisement

Table of Contents
loading