Image Conveying Unit (Re-Install To The Original Position) - Kyocera TASKalfa Pro 15000c Installation Manual

Hide thumbs Also See for TASKalfa Pro 15000c:
Table of Contents

Advertisement

The main unit setup procedure > Installation

(9) Image conveying unit (Re-install to the original position)

1
Hold the handles [B] and [C] then re-install the image conveying unit [A].
Take care not to damage the electrical components.
[B]
[A]
IMPORTANT
4 pins [C] on rails have to align with 4 holes [A] and [B] in frame of the image conveying unit. (Pay attention the
alignment otherwise the unit may drop.)
And also, if the frame goes over the pin, the unit becomes incline and service call error C2700 occurs. Make
sure to check the pin position again.
[C]
[C]
[B]
2-32
[CONFIDENTIAL]
[C]
[C]
[A]