Service Bulletin
(Service information)
서비스 호출 오류 C4600 에 대한 조치 (서비스 부품으로 먼지
Subject:
필터, LSU 구동 장치 등 설정)
P7240cdn, P6235cdn, P6230cdn, P7040cdn, P6035cdn,
P6130cdn,
Model:
M6635cidn, M6630cidn, M6235cidn, M6230cidn, TASKalfa 351ci,
M6535cidn, M6530cdn, M6035cidn, M6030cdn, TASKalfa 350ci
Field measures
Classification:
timing:
Phenomenon:
Type of change:
Depending on installation environment, dust gets into the main unit through the louver at the left side of the main
unit and adheres to the LSU drive part. The LSU cleaning motor rotation torque increases and servcie call error
C4600 (LSU cleaning motor error) might occur at the LSU slit glass cleaning (executed in a specified interval)
Follow the procedures 1-4 below when the above phenomenon occurs.
[Field measure] (Refer to
1. Clean around the louver of the middle left covr and lower left cover (2 points).
2. Attach the filter mounting holder (No2)to the above louver and set the dust filter (No1).
3. Check the condition of LSU drive unit (No4 or No5) and replace it if necessary.
(It is difficult to remove dust inside the LSU drive unit and it is recommended to replace the unit but not
mandatory.)
4. (Maintenance afterward) Clean the dust filter or replace it when visiting the customer. (Standard interval
to replace: 1 year) At the same time, check the condition of the the filter mounting holder secured and if
coming off, use the double sided tape set of 6 pcs. (No3) to replace the double sided tape.
[Service parts set for the field measure]
To implement the above, parts for field measure are set for service.
Parts for field measure
Set of 2 pcs. dust filters
Set of 2 pcs. filter mounting holders + 6
pcs. double sided tape
Set of 6 pcs. double sided tape
LSU drive unit (No4, 5)
At Set Up
Next Visit/Service Call
SC/Error
Image
Hardware
page 3-5
for procedure 1,2,4 and
No. in part table
No1
No2
No3
No4, 5
KYOCERA Document Solutions Inc.
Ref. No.
Next Periodic Maintenance
Information only
Paper Feeding/Conveying
Machine operation
Firmware and Software
6 and after
or procedure 3))
Remarks
Used at the 1st attachment and filter
replacement afterward
Used at the 1st attachment only
Used at the maintenance after implementing
this field measure
Used to replace if difficult to remove dust
For authorized KYOCERA engineers only.