Remove The Protection Covers; Connect The Dc Power Cables - ABB HVC Installation Manual

450 kw e-bus charger
Table of Contents

Advertisement

HVC 450 kW E-Bus Charger Installation Guide

5.7.1. Remove the protection covers

1.
Remove the 2 protection covers (B) from the connector blocks (A).
2.
Put the protection covers in a safe location as it will be installed again later on.

5.7.2. Connect the DC power cables

1.
Cut the wires of the DC power cable to the correct lengths to reach the connectors. Do
not make the wire routing too tight, or too loose.
2.
Strip 1.18 Inch of the insulation from the ends of the wires (B).
3.
Attach cable lug (A) at the end of the wires.
4.
Remove the nuts and washers (C) from the bolts (M12) of connector block (D).
5.
Insert the 2 wires (B) with the nuts and washers onto the bolts of connector block (D).
• From left to right:
Revision: 1.2
Date released: 16-08-2018
COMPANY CONFIDENTIAL
Page 71 of 128