HVC 450 kW E-Bus Charger Installation Guide
1.
Remove the protection covers from the optical connectors.
2.
Connect the two Ethernet fiber cables (C) onto the module D2 (A):
 Rx with Td D2;
 Tx with Rd D2.
3.
Connect the two CAN bus fiber cables (D) onto module D1 (B):
 Rx with Td D1;
 Tx with Rd D1.
Four fiber cables are not connected. Those fiber cables are meant for
spare.
4.
Bind the cables together and secure the loops loosely with a piece of tak-ty or ty-rap.
Make the loop bend radius of the fiber cables not smaller than 2.52 Inch,
otherwise the core of the fiber cable may break.
5.10.

Close the door of the Power Cabinet

Preconditions:
Key that were removed from the Power Cabinet
1.
Close the door (A).
2.
Lock the handle (B).