HVC 450 kW E-Bus Charger Installation Guide
Data cables
Functional description
Number of (twisted) pairs
Cross section
Min – Max external diameter to fit
through gland
Shielding
Conductor
Insulation
Characteristic impedance
Test Voltage
Ambient Temperature range
Core identification
Important: all cables must be resistant to being placed in the ground, submerged in
conduit.
All cables must have and isolation that are self-extinguishing and flame retardant
according to UL VW-1, CSA FT1.
All cables must be must meet the UL and the RoHS compliance.
Cables between ACS Control Module and Pantograph
These cables normally integrated within the ABB pole, however, these cables needed if the
charge system is ordered without ABB pole.
Power cables
Functional description
Number of cores
Cross section
Min – Max external
diameter to fit through
gland
Shielding
Conductor
Insulation
Nominal Voltage Uo/U
Test Voltage
Ambient Temperature
range
Core identification
Revision: 1.2
Date released: 16-08-2018
Interlock cable
2 x 2
18 – 14 AWG
0.20 – 0.39 Inch
Yes (tinned copper braid)
Fine strand copper wire
PVC or other material that can be
used outdoor and are UV-
protected
120 Ω ± 10%
1.5 kV
-40ºC to 80ºC
Acc. to DIN 47100
DC Power cable
1
350 – 600 MCM
1.06 – 1.38 Inch
No
Tinned copper or
aluminum conductor, fine
wire
stranded acc. to VDE
0295 cl.5/IEC Cl.5
Special rubber or PVC
(outdoor use, UV-
protected, oil resistant)
600/1000 Vac
900/1500 Vdc
6 kV
-40ºC to 105ºC,
permissible conductor
operating
temperature +90°C
CAN cable
1 x 2
20 – 18 AWG
inapplicable
Yes (tinned copper braid)
Fine strand copper wire
PVC or other material that can be
used outdoor and are UV-
protected
120 Ω ± 10%
1.5 kV
-40ºC to 80ºC
Acc. to DIN 47100
PE cable
1
2 AWG
0.51 – 0.83 Inch
No
Fine strand copper wire
acc. to VDE 0295 Cl. 5/
IEC 60228 Cl. 5
Special PVC (outdoor
use, UV-protected, oil
resistant)
600 Vac
4 kV
-40ºC to 105ºC
gn/ye or gn
DC- OVP Sensing cable
1
8 AWG
0.51 – 0.83 Inch
No
Bare copper, fine wired,
bunch stranded acc. to
VDE 0295 Cl.5/IEC Cl.5
Special rubber or PVC
(outdoor use, UV-
protected, oil resistant)
1.8/3 kVac
6 kV
-40ºC to 105ºC
COMPANY CONFIDENTIAL