HVC 450 kW E-Bus Charger Installation Guide
CAN cable connection in slave 1 HVC 150S:
A
Terminal block
B
CAN cable to master HVC 150
C
CAN cable from slave 2 HVC 150S
1.
Move the cable towards the terminal block (A).
2.
Strip 0.43 Inch of the insulation from the ends of the wires.
3.
Crimp a ferrule onto the end of the wire.
4.
Loosen the connector screws.
5.
Insert the wires into the connectors, see table below:
Functional description
CAN H In (to master HVC 150)
CAN L In (to master HVC 150)
CAN GND (to master HVC 150)
CAN H Out (from slave 2 HVC 150S) X286-10
CAN L Out (from slave 2 HVC 150S)
CAN GND (from slave 2 HVC 150S)
See also Appendix H Signal connection diagram.
6.
Tighten the connector screws.
Revision: 1.2
Date released: 16-08-2018
Connector
X286-1
X286-2
X286-3 or Shield Can In
X286-11
X286-12 or Shield Can Out
Wire color
Brown
White
Shield
Brown
White
Shield