Internet Connection - ABB HVC Installation Manual

450 kw e-bus charger
Table of Contents

Advertisement

HVC 450 kW E-Bus Charger Installation Guide
Data and control cables
Functional
ASC control
description
cable
Number of
12
cross
Twisted pair
No
Cross section
14 AWG
Min – Max
0.51 – 0.83
external
Inch
diameter to fit
through gland
Shielding
No
Conductor
Fine strand
copper wire
Insulation
PVC or
other
material that
can be used
outdoor and
are UV-
protected
Characteristic
impedance
Frequency
range
Test Voltage
2 kV
Nominal
600/1000
Voltage Uo/U
Vac
Ambient
-40ºC to
Temperature
80ºC
range
Core
Numbering
identification
Remarks
All cables must have and isolation that are self-extinguishing and flame retardant
according to UL VW-1, CSA FT1.
All cables must be meet the UL and the RoHS compliance.

4.5. Internet connection

In most cases the integrated 3G modem is used for wireless internet access. A customer SIM
card is not required. If there is no 3G signal available, a standard wired internet connection is
required. For this option, contact ABB Sales department (see Contact information on Page 13
for contact details).
Revision: 1.2
Date released: 16-08-2018
ACS heater
ACS CP/PE
cable
cable
3
2
No
No
14 AWG
16 AWG
0.20 – 0.39
0.20 – 0.39
Inch
Inch
No
Yes (tinned
copper
braid)
Fine strand
Fine strand
copper wire
copper wire
PVC or
PVC or
other
other
material that
material that
can be used
can be used
outdoor and
outdoor and
are UV-
are UV-
protected
protected
2 kV – 4 kV
2 kV
600/1000
300 Vac or
Vac
600 Vac
-40ºC to
-40ºC to
80ºC
80ºC
Numbering
Numbering
EMO cable
Distance
sensor
cable
4
4
No
No
20 – 18
20 – 18
AWG
AWG
0.20 – 0.39
0.20 – 0.39
Inch
Inch
No
No
Fine strand
Fine strand
copper wire
copper wire
PVC or
PVC or
other
other
material that
material that
can be used
can be used
outdoor and
outdoor and
are UV-
are UV-
protected
protected
2 kV – 4 kV
2 kV – 4 kV
300 Vac or
300 Vac or
600 Vac
600 Vac
-40ºC to
-40ºC to
80ºC
80ºC
Numbering
Numbering
or color
or color
Beacon light
WiFi cable
cable
4
1
No
Coaxial
20 – 18
AWG
0.20 – 0.39
inapplicable
Inch
No
Yes (tinned
copper braid)
Fine strand
Fine strand
copper wire
or solid
copper wire
PVC or
PVC or other
other
material that
material that
can be used
can be used
outdoor and
outdoor and
are UV-
are UV-
protected
protected
50 Ω
0.3 GHz - 6
GHz
2 kV – 4 kV
300 Vac or
600 Vac
-40ºC to
-40ºC to
80ºC
80ºC
Numbering
Coaxial
or color
Including on
both side N
(male)
connectors
COMPANY CONFIDENTIAL
Page 50 of 128

Hide quick links: