5Accif01.Fpls-001 - B&R Automation PC 2200 User Manual

Hide thumbs Also See for Automation PC 2200:
Table of Contents

Advertisement

2.3.4.5 5ACCIF01.FPLS-001

2.3.4.5.1 General information
Interface option 5ACCIF01.FPLS-001 is equipped with a POWERLINK and RS232 interface. In addition, 512 kB
nvSRAM is installed.
• 1x POWERLINK interface managing or controlled node
• 1x RS232 interface
• 512 kB nvSRAM
• Compatible with APC2100/PPC2100 and APC2200/PPC2200
2.3.4.5.2 Order data
Model number
Short description
Interface options
5ACCIF01.FPLS-001
Interface card - 1x RS232 interface - 1x POWERLINK interface -
512 kB nvSRAM - For APC2100/PPC2100/APC2200/PPC2200
- Only available with a new device
Optional accessories
Terminal blocks
0TB1210.3100
Connector 300 VDC - 10-pin female - Cage clamp terminal block
- Protected against vibration by the screw flange
2.3.4.5.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for this accessory
and may differ from those of the complete system. The data specified for the complete system applies
to the complete system in which this accessory is installed, for example.
Model number
General information
LED status indicators
B&R ID code
Certifications
CE
UL
HazLoc
Controller
nvSRAM
Size
Data retention
Read/Write endurance
Remanent variables in power failure mode
Interfaces
COM
Quantity
Type
Design
UART
Max. baud rate
POWERLINK
Quantity
Transfer
Type
Design
Transfer rate
Cable length
Electrical characteristics
Power consumption
Operating conditions
Pollution degree per EN 61131-2
Automation PC 2200 User's manual V 1.05 Translation of the original documentation
Table 103: 5ACCIF01.FPLS-001 - Order data
(for e.g. Automation Runtime, see Automation Help)
RS232, modem supported, not galvanically isolated
Max. 100 m between two stations (segment length)
Table 104: 5ACCIF01.FPLS-001 - Technical data
5ACCIF01.FPLS-001
L2, L3
0xE9B9
Yes
cULus E115267
Industrial control equipment
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
512 kB
20 years
Min. 1,000,000
256 kB
1
10-pin, male
16550-compatible, 16 byte FIFO
115 kbit/s
1
100BASE-TX
Type 4
2)
RJ45, shielded
100 Mbit/s
1.5 W
Pollution degree 2
Technical data
Figure
1)
91

Hide quick links: