5Accif01.Fpcs-000 - B&R Automation PC 2200 User Manual

Hide thumbs Also See for Automation PC 2200:
Table of Contents

Advertisement

Technical data

2.3.4.2 5ACCIF01.FPCS-000

2.3.4.2.1 General information
Interface option 5ACCIF01.FPCS-000 is equipped with a POWERLINK, RS485 and CAN bus master interface. In
addition, 32 kB FRAM is installed.
• 1x POWERLINK interface managing or controlled node
• 1x CAN bus master interface
• 1x RS485 interface
• 32 kB FRAM
• Compatible with APC2100/PPC2100 and APC2200/PPC2200
This interface option can only be operated with Automation Runtime.
2.3.4.2.2 Order data
Model number
Short description
Interface options
5ACCIF01.FPCS-000
Interface card - 1x RS485 interface - 1x CAN interface - 1x
POWERLINK interface - 32 kB FRAM - For APC2100/PPC2100/
APC2200/PPC2200 - Only available with a new device
Optional accessories
Terminal blocks
0TB1210.3100
Connector 300 VDC - 10-pin female - Cage clamp terminal block
- Protected against vibration by the screw flange
2.3.4.2.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for this accessory
and may differ from those of the complete system. The data specified for the complete system applies
to the complete system in which this accessory is installed, for example.
Model number
General information
LED status indicators
B&R ID code
Certifications
CE
UL
HazLoc
Controller
FRAM
Size
Data retention
Read/Write endurance
Remanent variables in power failure mode
Interfaces
COM
Quantity
Type
Variant
UART
Max. baud rate
POWERLINK
Quantity
Type
Variant
Transfer rate
Transfer
Line length
74
Table 69: 5ACCIF01.FPCS-000 - Order data
(for e.g. Automation Runtime, see Automation Help)
Max. 100 m between two stations (segment length)
Table 70: 5ACCIF01.FPCS-000 - Technical data
Automation PC 2200 User's manual V 1.05 Translation of the original documentation
5ACCIF01.FPCS-000
L1, L2, L3
0xED7C
Yes
cULus E115267
Industrial control equipment
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
32 kB
10 years
Min. 10
times/byte
12
32 kB
1
RS485, not galvanically isolated
10-pin, male
16550-compatible, 16 byte FIFO
115 kbit/s
1
Type 4
2)
RJ45, shielded
100 Mbit/s
100BASE-TX
Figure
1)

Hide quick links: