3.1.3 Changing the mounting type (removing/installing the mounting plate)

1. Disconnect the power supply cable to the Automation PC (disconnect the power cable). Disconnect from all
sources and poles.
2. Carry out electrostatic discharge at the ground connection.
3. Disconnect all connected cables.
4. Remove the Automation PC. To do this, remove the M5 screws and remove the Automation PC.
5. The 4 Torx screws (T20) marked in the figure below must be removed.
6. Remove the mounting plate and reinstall it using the selected mounting method with the Torx screws (T20)
removed earlier (max. tightening torque 0.5 Nm).
7. The Automation PC can now be installed again. Note changed spacing for air circulation, etc. For more
information, see section
Automation PC 2200 User's manual V 1.05 Translation of the original documentation
Figure 30: Removing the Torx screws
Figure 31: Tightening the Torx screws
"Mechanical properties" on page
21.