Environmental Properties; Temperature Specifications - B&R Automation PC 2200 User Manual

Hide thumbs Also See for Automation PC 2200:
Table of Contents

Advertisement

Technical data

2.2.3 Environmental properties

2.2.3.1 Temperature specifications

Because it is possible to combine different system units with a monitor/panel option and interface option, the
following tables provide a component-dependent overview of the maximum, minimum and typical possible ambient
temperatures resulting from these combinations.
Information:
The minimum and maximum specified ambient temperatures were determined under worst-case con-
ditions for operation. Experience has shown that higher ambient temperatures can be achieved with
typical applications in Microsoft Windows, for example. The relevant test and assessment must be
carried out individually by the user on site (reading out the temperatures in BIOS or using the B&R
Control Center, for example).
Information about worst-case conditions
• Power Thermal Utility from Intel for simulating 100% processor utilization
• BurnInTest tool (BurnInTest V8.1 Pro by PassMark Software) for simulating 100% interface utilization using
loopback adapters (USB interfaces)
• Maximum expansion and power consumption of the system
2.2.3.1.1 Maximum ambient temperature for worst-case operation
All temperature specifications in degrees Celsius
(°C) at 500 m above sea level, non-condensing
The maximum ambient temperature is typically derated
1°C per 1000 meters starting at 500 m above sea level.
Maximum ambient temperature (accessories)
CFast card
Monitor/Panel option
Interface option
26
Maximum worst-case ambient temperature (system unit 5APC2200.ALxx-000)
5APC2200.AL02-000
(E3930 1.3 GHz)
5CFAST.xxxx-00 ≥ E0
5CFAST.xxxx-10
5ACCLI01.SDL0-000
5ACCLI03.SDL4-000
5ACCIF01.ICAN-000
5ACCIF01.FPCC-000
5ACCIF01.FPCS-000
5ACCIF01.FPLK-000
5ACCIF01.FPLS-000
5ACCIF01.FPLS-001
5ACCIF01.FPSC-000
5ACCIF01.FPSC-001
5ACCIF01.FSS0-000
5ACCIF03.CETH-000
Table 7: Maximum ambient temperature for worst-case operation
Automation PC 2200 User's manual V 1.05 Translation of the original documentation
5APC2200.AL04-000
(E3930 1.3 GHz)
55
55
5APC2200.AL14-000
5APC2200.AL18-000
(E3940 1.6 GHz)
(E3940 1.6 GHz)
50
50