Sdl Cables; 5Casdl.0Xxx-00 - B&R Automation PC 2200 User Manual

Hide thumbs Also See for Automation PC 2200:
Table of Contents

Advertisement

6.5.2 SDL cables

6.5.2.1 5CASDL.0xxx-00

6.5.2.1.1 General information
5CASDL.0xxx-00 SDL cables are designed for use in fixed installations. For flexible installations (e.g. swing arm
systems), the use of 5CASDL.0xxx-03 SDL flex cables is required.
Caution!
The cable is only permitted to be connected/disconnected when the power is switched off.
6.5.2.1.2 Order data
Model number
Short description
SDL cables
5CASDL.0008-00
SDL cable - 0.8 m
5CASDL.0018-00
SDL cable - 1.8 m
5CASDL.0050-00
SDL cable - 5 m
5CASDL.0060-00
SDL cable - 6 m
5CASDL.0100-00
SDL cable - 10 m
5CASDL.0150-00
SDL cable - 15 m
5CASDL.0200-00
SDL cable - 20 m
5CASDL.0250-00
SDL cable - 25 m
5CASDL.0300-00
SDL cable - 30 m
Table 217: 5CASDL.0008-00, 5CASDL.0018-00, 5CASDL.0050-00, 5CASDL.0060-00, 5CASDL.0100-00,
5CASDL.0150-00, 5CASDL.0200-00, 5CASDL.0250-00, 5CASDL.0300-00 - Order data
6.5.2.1.3 Technical data
Information:
The following specified characteristic data, features and limit values are only valid for this accessory
and may differ from those of the complete system. The data specified for the complete system applies
to the complete system in which this accessory is installed, for example.
Model number
General information
Certifications
CE
UL
HazLoc
DNV GL
GOST-R
Cable construction
Wire cross section
Shield
Complete shielding
Outer jacket
Material
Color
Labeling
Connector
Type
Connection cycles
Table 218: 5CASDL.0008-00, 5CASDL.0018-00, 5CASDL.0050-00, 5CASDL.0060-00, 5CASDL.0100-00,
5CASDL.0150-00, 5CASDL.0200-00, 5CASDL.0250-00, 5CASDL.0300-00 - Technical data
Automation PC 2200 User's manual V 1.05 Translation of the original documentation
5CASDL.
5CASDL.
5CASDL.
0008-00
0018-00
0050-00
Temperature: B (0 - 55 °C)
Humidity: B (up to 100%)
Vibration: A (0.7 g)
EMC: B (bridge and open deck)
2)
-
Yes
28 AWG
E74020-C (UL) AWM STYLE 20176 80°C 30V VW-1 DVI DIGITAL LINK
5CASDL.
5CASDL.
5CASDL.
0060-00
0100-00
0150-00
Yes
cULus E115267
Industrial control equipment
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
Temper-
ature:
B (0 - 55°C)
Humidity:
B (up to 100%)
Vibration:
A (0.7 g)
EMC: B
(bridge
and open
deck)
2)
-
Individual cable pairs, entire cable
Tinned copper braiding, optical coverage > 85%
PVC
Black
2x DVI-D (24+1), male
100
Accessories
Figure
5CASDL.
5CASDL.
0200-00
0250-00
1)
Temperature: B (0 - 55 °C)
Humidity: B (up to 100%)
Vibration: A (0.7 g)
EMC: B (bridge and open deck)
2)
Yes
24 AWG
5CASDL.
0300-00
193

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents