8.27.2

Rotation monitoring

Function description
The converter monitors the speed or velocity of a machine component via an electromechanic
or electronic encoder, e.g. a proximity switch. Examples of how the function can be used:
• Gearbox monitoring for traction drives and hoisting gear
• Drive belt monitoring for fans and conveyor belts
• Blocking protection for pumps and conveyor belts
The converter checks whether the encoder consistently supplies a 24 V signal during motor
operation. If the encoder signal fails for time p2192, the converter signals fault F07936.
Figure 8-74
Parameter
Parameter
r0722
p2192[D]
p2193[D]
p3232[C]
Additional information is provided in the List Manual (the parameter list and function diagram
8013).
Function diagrams
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
Function plan and time response of the speed monitoring
Description
CO/BO: CU digital inputs, status
Load monitoring, delay time
Load monitoring configuration
BI: Load monitoring, failure detection
Torque monitoring (Page 332)
Advanced commissioning
8.27 Monitoring the driven load
Factory setting
-
10 s
1
1
331