Downloading The Converter Settings; Converter Without Enabled Safety Functions; Automatic Download From The Memory Card; Manual Download From The Memory Card Using Startdrive - Siemens SINAMICS G110M Operating Instructions Manual

Distributed converter for simogear geared motors
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

10.2

Downloading the converter settings

10.2.1

Converter without enabled safety functions

10.2.1.1

Automatic download from the memory card

Overview
We recommend that you insert the memory card before switching on the converter. The
converter automatically imports its settings from the inserted memory card.
Precondition
The following requirements apply:
• The converter power supply has been switched off.
• The converter settings are not protected against copying.
Function description
Procedure
1. Insert the memory card into the converter.
2. Switch on the power supply for the converter.
3. The converter loads the settings from the memory card.
4. After loading, check whether the converter outputs Alarm A01028.
– Alarm A01028:
– No alarm A01028:
You have transferred the settings to the converter.
10.2.1.2

Manual download from the memory card using Startdrive

Overview
If you have backed up the settings of several converters on the memory card, the settings
download must be started manually.
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
Download with active know-how protection with copy protection (Page 375)
The loaded settings are not compatible with the converter.
Delete the alarm with p0971 = 1.
Recommission the drive.
The converter accepts the settings that have been loaded.
Corrective maintenance
10.2 Downloading the converter settings