Adapt The Default Setting Of The Inputs And Outputs; Digital Inputs - Siemens SINAMICS G110M Operating Instructions Manual

Distributed converter for simogear geared motors
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

Advanced commissioning

8.4 Adapt the default setting of the inputs and outputs

8.4
Adapt the default setting of the inputs and outputs
Overview
In the converter, the input and output signals are interconnected with specific converter
functions using special parameters. The following parameters are available to interconnect
signals:
• Binectors BI and BO are parameters to interconnect binary signals.
• Connectors CI and CO are parameters to interconnect analog signals.
The following chapters describe how you adapt the function of individual converter inputs and
outputs using binectors and connectors.
8.4.1

Digital inputs

Function description
Interconnect the status parameter of the digital input with a binector input of your choice.
Binector inputs are designated in the parameter list with "BI".
162
BI: pxxxx
2
r0722.1
1
5
3
r0722.0
4
2
r0722.3
1
5
3
4
r0722.2
Interconnecting signals in the converter (Page 408)