3.12
Default settings of inputs and outputs (CU240D-2)
Default setting 1: "Conveyor system with 2 fixed frequencies"
DO 0: p0730, DO 1: p0731
Fixed speed setpoint 3: p1003, fixed speed setpoint 4: p1004, fixed speed setpoint active: r1024
Speed setpoint (main setpoint): p1070[0] = 1024
DI 4 and DI 5 = high: the inverter adds the two fixed speed setpoints
Default setting 2: "Conveyor system with Basic Safety"
DO 0: p0730, DO 1: p0731
Fixed speed setpoint 1: p1001, fixed speed setpoint 2: p1002, fixed speed setpoint active: r1024
Speed setpoint (main setpoint): p1070[0] = 1024
DI 0 and DI 1 = high: the inverter adds the two fixed speed setpoints.
SINAMICS G120D converter
Getting Started, 07/2016, FW V4.7 SP6, A5E38556189B AA
3.12 Default settings of inputs and outputs (CU240D-2)
DI 0: r0722.0, ..., DI 5: r0722.5
DI 0: r0722.0, ..., DI 5: r0722.5
Installation
49