SIGLENT SDS1000X-E Series User Manual page 125

Digital oscilloscope
Hide thumbs Also See for SDS1000X-E Series:
Table of Contents

Advertisement

SDS1000X-E&SDS1000X-U User Manual
set value.
If you have set either Data1's or Data2's value, and the signal has a data is
the same as that value. If you have set both Data1's and Data2's value, the
signal should has two consecutive data, the first data's value is Data1,
second data value is Data2.
(Note: If the data's value is 0xXX, any data value will be matched)
10 Address & Data — the oscilloscope will be triggered when the following
conditions are satisfied.
The address's length must be 10 bits and the address's value is the same
as set value.
If you have set either Data1's or Data2's value, and the signal has a data is
the same as that value. If you have set both Data1's and Data2's value, the
signal should has two consecutive data, the first data's value is Data1,
second data value is Data2.
(Note: If the set value is 0xXX, any data value will be matched)
93