Digital oscilloscope
Hide thumbs Also See for SDS1000X Series:

Advertisement

Quick Links

Quick Start
SDS1000X Series
Digital Oscilloscope

Advertisement

Table of Contents
loading

Summary of Contents for SIGLENT SDS1000X Series

  • Page 1 Quick Start SDS1000X Series Digital Oscilloscope...
  • Page 2: General Safety Summary

    The instrument is grounded through the protective earth Note: SIGLENT is the registered trademark of SIGLENT TECHNOLOGIES CO., LTD. which will eventually damage the instrument. So keep well conductor of the power line. To avoid electric shock, please ventilation and inspect the intake and fan regularly.
  • Page 3: Table Of Contents

    SIGLENT SIGLENT General Care and Cleaning Safety Terms and Symbols Contents Care Terms on the product. These terms may appear on the product: Do not store or leave the instrument in direct sunshine for long periods of time. General Safety Summary...
  • Page 4: Quick Start

    The consigner or carrier will be responsible for damages to the instrument resulting from shipment. SIGLENT would not provide free maintenance or replacement. 2. Inspect the instrument If there are instruments found damaged, defective or...
  • Page 5: Adjust The Supporting Legs

    Compensation Signal Output Terminal Connect the Probe Ground Terminal SIGLENT provides passive probe for the SDS1000 series 3. Use the probe to connect the CH1 Input Terminal and the oscilloscope. Please refer to corresponding Probe User Compensation Signal Output Terminal on the front panel.
  • Page 6: Probe Compensation

    SIGLENT SIGLENT Probe Compensation The Front Panel 6. Test the other channels in the same method. If the actual square waveforms does not match that in the figure above, please perform “Probe Compensation” . You should properly compensate the probe at first use of it.
  • Page 7: The Rear Panel

    The instrument can be connected to network via this interface to perform remote control . 3. USB Device SDS1000X series support SCPI Quickly enter into the Roll mode. remote control commands, User can Press the button to open trigger menu.
  • Page 8 SIGLENT SIGLENT Interval Trigger Pattern Trigger Runt Trigger I2C Trigger The time interval from the rising edge (or falling edge) of Identify a trigger condition by looking for a specified pattern. Runt trigger includes positive runt trigger and negative After setting the serial 1 or 2 to I2C type in trigger menu,...
  • Page 9: Vertical Control

    SIGLENT SIGLENT Vertical Control SPI Trigger Press the button to set to Auto trigger mode. After setting the serial trigger to SPI type in trigger menu, you Vertical Scale :Set the vertical scale of current can select to trigger on MISO data or MOSI data. The data waveform.
  • Page 10: Run Control

    SIGLENT SIGLENT Run Control :Press the button to open the WaveGen menu. Decoding for I2C signal of 7 address is described in the following figure. SDS1000X-S provides built-in signal generator function. Ten types of signal including Sine, Square, Ramp, Press the button to enable the waveform auto Pulse, DC, Noise, Cardiac, Gaus Pulse, Exp Rise and ExpFall are supported.The max output frequency is 25MHz...
  • Page 11: Universal Knob

    SIGLENT SIGLENT Universal Knob Function Menus :This button is a shortcut key for clear function. Press the button to enter the sample menu. When the measurement statistics is ON, press the button You can set the acquisition mode (Normal/Peak-Detect to clear the count and recount it. When persist is enabled /Average/ERes), interpolation mode(Sinx/X or linear) , press the button to clear persist.
  • Page 12: User Interface

    1. Product Logo Channel Coupling Display the selected coupling 8. Sample Rate/Memory Depth SIGLENT is the registered mode of the current channel.All modes are: DC/AC/GND. Display the current sample rate and memory depth of the trademark of our company. 1.00V/div oscilloscope.
  • Page 13: Using Security Lock

    (5)Restart the instrument and then insert the USB to check it. (4)Change the setting of trigger holdoff. (6)If it is still in abnormal use, please contact with SIGLENT. 18 SDS1000X Quick Start SDS1000X Quick Start 19...