Total Access 850 System Manual
Nx56k/64k Port (J1)
The Total Access 850 system provides a single V.35 Winchester-style connection on the rear of the chassis
(as defined in Table 15).
Pin/CCIT
A/101
Protective ground (PG)
B/102
Signal ground (SG)
C/105
Request to send (RTS) from DTE
D/106
Clear to send (CTS) to DTE
E/107
Data set ready (DSR) to DTE
E/109
Data carrier detect
H/—
Data terminal ready (DTR) from DTE
J/—
Ring indicator (RI)
R/104
Received data (RD-A) to DTE
T/104
Received data (RD-B) to DTE
Alarm Relay Connection (P5)
This connection alerts the user when a selected alarm condition exists. Alarm relay contacts are open
during normal operation. The alarm relay contacts close in the event of a local alarm condition or the
receipt of an alarm from the T1 carrier. In a carrier alarm condition such as a Red, Yellow, or Blue
(unframed all 1s), various alarm contacts in the PSU close. Carrier alarm conditions cause the
Total Access 850 to initiate trunk processing. The following chain of events then occur:
1. MJ will be directly shorted to MJR.
2. MJV will be directly shorted to MJVR.
Contacts MJ and MJR can be overridden manually during an alarm condition by pressing the ACO
pushbutton on the PSU faceplate. If the 3-Amp power fuse on the PSU trips, the -48ALM relay will close,
providing a -48 VDC signal on that pin. This alarm cannot be overridden by the ACO pushbutton. Refer to
Table 17 for alarm notifications.
Table 16 shows the pinout for the Alarm Relay connector.
Pin
Name
1
-48 ALM
2
MJVR
3
MJV
4
MJR
5
MJ
64203376L1-1B
Table 15. V.35 Winchester Pinout
Description
Table 16. Alarm Relay Connector Pinout
DC alarm output.
Closes when a selected alarm condition is present.
Common connection between external circuitry and NC or NO terminal.
Major alarm audible common
Major alarm audible
© 2004 ADTRAN, Inc.
Section 2 Engineering Guidelines
Pin/CCIT
V/115
RX clock (RC-A) to DTE
X/115
RX clock (RC-B) to DTE
P/103
Transmitted data (TD-A) from DTE
S/103
Transmitted data (TD-B) to DTE
Y/114
TX clock (TC-A) to DTE
AA/114
TX clock (TC-B) to DTE
U/113
External TX clock (ETC-A) from DTE
W/113
External TX clock (ETC-B) from DTE
NN/—
Test mode (TM) to DTE
Description
Description
37