1175043L3 64203376L1-1B August 2004 TOTAL ACCESS 850 System Manual Total Access 850 Chassis T1 Bank Controller Unit (BCU) T1 BCU with DSX Port T1 Router Control Unit (RCU) with TDM Software T1 RCU with ATM Software 3rd Generation T1 RCU...
Total Access ® is a registered trademark of ADTRAN, Inc. To the Holder of the Manual The contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice.
Total Access 850 System Manual Revision History Document Revision Date April 2004 August 2004 Conventions Notes provide additional useful information. Cautions signify information that could prevent service interruption. Warnings provide information that could prevent damage to the equipment or endangerment to human life.
Advance notification and the opportunity to maintain uninterrupted service are given. If experiencing difficulty with this equipment, please contact ADTRAN for repair and warranty information. The telephone company may require this equipment to be disconnected from the network until the problem is corrected or it is certain the equipment is not malfunctioning.
Page 7
Total Access 850 System Manual Affidavit Requirements for Connection to Digital Services • An affidavit is required to be given to the telephone company whenever digital terminal equipment without encoded analog content and billing protection is used to transmit digital signals containing encoded analog content which are intended for eventual conversion into voice band analog signal and transmitted on the network.
Total Access 850 System Manual Industry Canada Compliance Information The Industry Canada Certification label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department of Commerce does not guarantee the equipment will operate to the user's satisfaction.
Each ADTRAN product contains a single license for ADTRAN supplied software. Pursuant to the Licensing Agreement, you may: (a) use the software on the purchased ADTRAN device only and (b) keep a copy of the software for backup purposes. This Agreement covers all software installed on the system as well as any software available on the ADTRAN website.
Page 12
Customer Service, Product Support Information, and Training Post-Sale Support Your reseller should serve as the first point of contact for support. If additional support is needed, the ADTRAN Support web site provides a variety of support services such as a searchable knowledge base, updated firmware releases, latest product documentation, service request ticket generation and trouble-shooting tools.
Preconfigured Total Access 850 packages are available. The Total Access 850 is a modular device with two common slots, six access slots for FXS, FXO, Dual V.35, and UBR1TE modules, and two slots for special access modules. The FXS, FXO, Dual V.35, and UBR1TE modules are supported in the Router Control Unit (RCU);...
Performance statistics per TR54016, T1.403, RFC1406 • Alarm reporting per TR54016, T1.403 MODULES The Total Access 850 system offers several different system modules (including the power supply), system resource modules, and access modules. System Modules • Bank Controller Unit (BCU) (P/N 1200373L1) •...
The unit consists of a main circuit board and daughter card and inserts directly in the controller slot on the Total Access 850 shelf. An 8-position DIP-switch is mounted on the daughter card and is used for T1 provisioning and clocking.
(ADPCM) resources are also built-in for up to 16 ports. Power Supply Unit (P/N 1175006L2) The Total Access 850 PSU is a common module plug-in unit designed to supply power to the system. The faceplate contains a momentary ACO pushbutton, a ring voltage Enable/Disable pushbutton, a Bank Alarm LED, Ring LED, and a power LED.
U-BR1TE Access Module (P/N 1180020L1) The UBR1TE is a module that plugs into a single access slot of the Total Access 850. It provides an ISDN U-interface and allows transport of Basic Rate 2B+D information over T1 carriers and twisted pair wiring.
Total Access 850 System Manual EQUIPMENT DIMENSIONS The Total Access 850 chassis is 8.5” W, 11” D, and 3.5” H and can be mounted in a 19-inch or 23-inch rack (mounting brackets included in shipment). All other equipment (modules) fit inside the base unit.
Blinking GREEN DIP-Switch Settings The Total Access 850 BCU can be provisioned from DIP-switches (S1) mounted on the PCB, or through screen menus accessed via the faceplate loopback options are found on the DIP-switch panel. Table 2 gives DIP-switch provisioning information.
Page 27
Enables or disables the TR-08 signaling option. When enabled, S1-1 is ignored. Enabled Disabled Enables the CSU loopback function. When this switch is enabled, the Total Access 850 will respond to CSU loopbacks sent from a remote network device or test equipment. Disabled OFF* Enabled Determines the clock source options for the Total Access 850 system.
Faceplate Bantam Jack The faceplate bantam jack provides a means to monitor the network T1 connected to the rear of the Total Access 850 chassis. The jacks accept standard 310-type bantam plugs. Figure 2 display the bantam jack monitoring points.
Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 4 gives a description of all faceplate LEDs for the T1 RCU when used with the Total Access 850 system. For these LEDs... This color light...
Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 6 gives a description of all faceplate LEDs for the T1 RCU when used with the Total Access 850 system. Receiver Circuitry Clock and Data...
Faceplate Bantam Jack The faceplate bantam jack provides a means to monitor the network T1 connected to the rear of the Total Access 850 chassis. The jacks accept standard 310-type bantam plugs. Figure 5 display the bantam jack monitoring points.
Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 8 gives a description of all faceplate LEDs for the SDSL RCU when used with the Total Access 850 system. For these LEDs... This color light...
For systems using PSU (P/N 1175006L2) – Depress the Ring Enable pushbutton to isolate the ring voltage from the Total Access 850. Figure 6 shows the Total Access 850 backplane, and Table 10 on page 34 gives the backplane connections. 64203376L1-1B Description ON* (down) The unit powers up in the firmware update mode.
Section 2 Engineering Guidelines Table 10. Total Access 850 Backplane Connections Ref Des wire-wrap strip 50 pin amphenol wire-wrap strip wire-wrap strip 4 pin jack 3-lug terminal RJ-48/E-NET RJ-48/T1 RJ-48/FT1 RJ-48/MAINT V.35 10/100BaseT Connection (JP1) Only the 3rd Generation RCUs provide a 10/100BaseT connection. All other available RCU Ethernet interfaces are 10BaseT.
Class A3 T1 Span Power Voltage coming from the network. The Total Access 850 system provides a single T1 port (located on the rear panel) and complies with the applicable ANSI and AT&T™ standards. The T1 interface provides the following functions: •...
(EIA-232) on the rear of the chassis connects to a computer or modem and provides the CRAFT following functions: • Accepts EIA-232 input from a PC or a modem for controlling the Total Access 850. • Baud rate is user-configurable. •...
Total Access 850 System Manual Nx56k/64k Port (J1) The Total Access 850 system provides a single V.35 Winchester-style connection on the rear of the chassis (as defined in Table 15). Pin/CCIT Description A/101 Protective ground (PG) B/102 Signal ground (SG)
Clock Wire-Wrap Strip (P1) A single wire-wrap strip is provided on the Total Access 850 backplane for connection to an external bits clock. The external bits clock may be used to provide master timing for the Total Access 850 system.
Table 18 on page 39 shows the pinout for the T1 wire-wrap connector. The Total Access 850 provides dual T1 connection points. In all cases, only one of the connection points is used. When wire-wrapping of the T1 is utilized (using P3), a blank plug must be placed in the primary T1 connection (JP2).
Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 20 gives a description of all faceplate LEDs for the Quad FXS Module when used with the Total Access 850 system. 20 AWG 16 AWG...
Quad FXS Access Module (P/N 1175408L2) The Quad FXS Access Modules use the 50-pin female amphenol connector on the rear of the Total Access 850 chassis to provide the interconnect wiring for the four analog circuits on each access module.
Figure 9 shows the pinout connection for the amphenol connector. See Figure 7 on page 38 for closer detail. Figure 9. Quad FXS Connector Pin Assignments Specifications Table 21 provides the detailed specifications for the Total Access 850 Quad FXS Module. Table 21. Quad FXS Module Specifications Power...
Quad FXO Access Module (P/N 1175407L1) The Quad FXO Access Modules use the 50-pin female amphenol connector on the rear of the Total Access 850 chassis to provide the interconnect wiring for the four analog circuits on each access module.
Figure 10 shows the pinout connection for the amphenol connector. See Figure 7 on page 38 for closer detail. Figure 10. Quad FXO Connector Pin Assignments Specifications Table 24 provides the detailed specifications for the Total Access 850 Quad FXO Module. Table 24. Quad FXO Module Specifications Power...
Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 26 gives a description of all faceplate LEDs for the UBR1TE Module when used with the Total Access 850 system. Table 26. UBR1TE Module Faceplate LEDs For these LEDs...
Table 27. UBR1TE Slot/Amphenol Assignment Total Access 850 Slot DIP-Switch Settings The Total Access 850 UBR1TE Module can be provisioned from either the DIP-switches (S1) mounted on the PCB, or through screen menus accessed via the faceplate DIP-switch setting details. Switch...
Page 47
Total Access 850 System Manual Table 28. BCU DIP-Switch S1 Options (Continued) Switch Function S1-2 Tandem Office Installation S1-3 Service for: S1-4 S1-3: B1 S1-5 S1-4: B2 S1-5: D S1-6 Zero Byte Substitution 64203376L1-1B Section 2 Engineering Guidelines Description Indicates whether the unit is installed in a Tandem Office installation.
Section 2 Engineering Guidelines Specifications Table 29 provides the detailed specifications for the Total Access 850 UBR1TE Module. Table 29. UBR1TE Module Specifications Line Operating Mode Data Rate Signal Format Transmit Power BR1/10 compatible equipment. Interface Dimensions Weight Current Draw...
Total Access 850 System Manual OCU DP Access Module (P/N 1180005L1) The OCU DP Access Module may be used for intra-building networks only. This interface should not be connected to public networks. The OCU DP module is a single port access module used to provide the interface between a DS0 time slot on the T1 and a 4-wire DDS device at the customer premises.
The Total Access 850 can support a maximum of seven V.35 interfaces. V.35 ports provided by the Dual V.35 module are accessed on the front of the Total Access 850. This module is currently only supported by the TDM version of the T1 RCU. An ADTRAN 35 ft DB-26/V.35 adapter cable is required (P/N 1200167L1).
Faceplate LEDs The faceplate LEDs provide status information using a color coded message format. Table 37 on page 53 gives a description of all faceplate LEDs for the DSX-1 Module when used with the Total Access 850 system. Total Access 850 System Manual –...
T1 | RXDATA-TIP UNUSED R | TXDATA-RING T | TXDATA-TIP 6,7,8 UNUSED Specifications Table 39 provides the detailed specifications for the Total Access 850 DSX-1 Module. Table 39. DSX-1 Module Specifications Capacity Framing Line Build Out Line Coding Line Rate...
UNPACK AND INSPECT THE SYSTEM Each Total Access 850 is shipped in its own cardboard shipping carton. Open each carton carefully and avoid deep penetration into the carton with sharp objects. After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier, and then contact ADTRAN Customer Service (see Customer Service, Product Support Information, and Training in the front of this manual).
Total Access 850 System Manual Contents of ADTRAN Shipments Your ADTRAN shipment of the Total Access 850 chassis includes the following items: • The Total Access 850 Base Unit • The Total Access 850 Series System CD • Wallmount brackets and screws •...
As shipped, the Total Access 850 is set to factory default conditions. After installing the chassis and any access modules, the Total Access 850 is ready for power-up. To power-up the unit, ensure that the unit is properly connected to an appropriate power source.
Total Access 850 System Manual DC Powered Systems The DC powered Total Access 850 comes equipped with a DC Power supply to furnish the voltages necessary for proper backplane operation. As shipped, the Total Access 850 is set to factory default conditions.
Section 3 Network Turnup Procedure MOUNTING OPTIONS The Total Access 850 chassis may be wallmounted or installed in a 19-inch or 23-inch rack. Wallmount brackets are included with the chassis. For a rackmount installation, the Total Access 850 Base Unit allows flush-face mount, face-forward mount, center mount, and rear mount.
Total Access 850 System Manual INSTALLING MODULES Figure 1 shows the slot numbering designation as viewed from the front of the Total Access 850 chassis. The functionally identical option slots only accept Total Access 850 access modules, and the controller slots only accept Total Access 850 controller modules.
Disengaging the captured screw allows removal of the locking bar. To install Controller Resource and Access Modules for the Total Access 850, follow the steps outlined below. 1. Hold the access module by the faceplate while supporting the bottom side.
Total Access 850 System Manual OCU DP Access Module (P/N 1180005L1) Shipping Contents The ADTRAN shipment of the OCU DP Access Module includes the following items: • OCU DP Access Module • OCU DP Access Module Job Aid E&M/TO Access Module (P/N 1180402L1) Shipping Contents The ADTRAN shipment of the E&M/TO Access Module includes the following items:...
This section provides detailed descriptions of all menu options and configuration parameters available for the Total Access 850 when used with a Router Control Unit (RCU). This section does not apply to systems that employ a Bank Control Unit (BCU).
Page 66
Telnet Security Levels ........... 80 Total Access 850 System Manual...
Section 4 User Interface Guide NAVIGATING THE TERMINAL MENU To access the terminal menus and management features of the Total Access 850, connect the unit to a VT100 terminal (or VT100 terminal emulator) via the interface on the front of the unit or the rear CRAFT interface on the backplane.
Underlined field Additional Terminal Menu Window Features • DS0 Status – displays the current mapping of DS0s in the Total Access 850 system. DS0s mapped to the router display r, unmapped DS0s display –, and all other DS0s display *. •...
To do this... Review and monitor general system information for the Total Access 850 Set up the operational configuration for the Total Access 850 Upgrade firmware, perform config transfers, ping, and access terminal mode Review and configure settings for all interfaces (including installed modules) Configures the Layer 2 protocol for the various interfaces (T1, Ethernet, etc.)
Status Read-only permission for all menu items - minimum rights MENU DESCRIPTIONS The remainder of this section describes Total Access 850 menu and submenu options. To help you follow the terminal menu hierarchy, the following notations are used: > S...
Total Access 850 System Manual YSTEM menu provides basic information about the unit as well as data fields for editing YSTEM information. Figure 3 displays the submenus that are available when you select this menu item. > S YSTEM YSTEM Provides a user-configurable text string for the name of the unit.
Page 74
> S YSTEM YSTEM PTIME Displays the length of time the Total Access 850 system has been running. Each time you reset the system, this value resets to 0 days, 0 hours, 0 min and 0 secs. > D YSTEM Displays the current date and time, including seconds.
Total Access 850 System Manual YSTEM ONFIG Set up the unit’s operational configuration from the included in this menu. > M YSTEM ONFIG ANAGEMENT Set up the CRAFT P ELNET > M YSTEM ONFIG ANAGEMENT Set up the CRAFT P parameters from this menu.
Page 76
ONFIG ANAGEMENT Activate the Telnet access and set up the various Telnet parameters from this menu. The Total Access 850 supports up to five simultaneous Telnet sessions. The Total Access 850 ships with default Telnet Access parameters of: guest (user), password (password).
Page 77
Total Access 850 System Manual > M YSTEM ONFIG ANAGEMENT Set up the Telnet authentication method from this menu. The choices are , and OCAL ADIUS ADIUS OCAL Authentication first, and if that fails, it will try Radius Authentication. will try Radius authentication first, and if that fails, it will try Local Password authentication. The default is...
Page 78
YSTEM ONFIG ANAGEMENT Provides a list of all Telnet sessions currently active on the Total Access 850 system. Displays the index number of the Telnet user. Displays the text string entered in the Telnet configuration for this user. Displays the TCP port used for this Telnet session.
Page 79
, SNMP access is denied. When set to on the configuration. The factory default is > M YSTEM ONFIG ANAGEMENT When enabled, the Total Access 850 inserts a delay before transmitting a created trap for the SNMP session. > M YSTEM ONFIG ANAGEMENT Set up the SNMP communities parameters from this menu.
Page 81
> S YSTEM ONFIG YSLOG Configure the unit Syslog client for use with a Syslog server (supplied with ADTRAN Utilities or available on most Unix platforms) from this menu. For additional information, reference RFC3164: The BSD Syslog Protocol. > S...
RFC3164: The BSD Syslog Protocol. The lower the log level, the more messages that will be generated. Setting reporting levels to DEBUG may negatively affect the performance of the IAD, including causing the IAD to reset. ADTRAN recommends using DEBUG for only short periods of time, and for debug purposes only. > S...
Page 83
Total Access 850 System Manual SYSLOG using Terminal Mode Another option for configuring syslog is using the terminal mode command log dump <logname>. The logname must be all CAPS and be one of the following names: FATAL ALERT CRITICAL ERROR...
Page 84
YSTEM ONFIG YSLOG Minimum required level for sending UDP log messages. > S YSTEM ONFIG YSLOG This parameter is for ADTRAN internal use only. > S YSTEM ONFIG YSLOG Minimum required level for sending TCP log messages. > S YSTEM...
Page 85
DSLAM. Messages are only generated for ATM products. > S YSTEM ONFIG YSLOG This parameter is for ADTRAN internal use only. > S YSTEM ONFIG YSLOG Minimum required level for sending log messages about WAN physical or Layer 1 connection.
Page 86
Minimum required level for sending XMODEM log messages for firmware and configuration transfers. > S YSTEM ONFIG YSLOG This parameter is for ADTRAN internal use only. > S YSTEM ONFIG YSLOG Minimum required level for sending frame relay log messages.
Page 87
Total Access 850 System Manual > N YSTEM ONFIG ETWORK Activate the network time and configure the server type, time zone and various other network time parameters from this menu. > N YSTEM ONFIG ETWORK The unit time can be entered manually from the NTP/SNTP server.
Page 89
In addition, TFTP server. To support these transfers, ADTRAN delivers a TFTP program with the unit called TFTP Server. You can configure any PC running Microsoft Windows with this software, and store a configuration file. Before using TART default gateway (if required).
Page 90
TILIZATION ERFORMANCE > P TILIZATION ERFORMANCE Max CPU utilization since the last Total Access 850 restart. Max CPU utilization in the last second. This is the most current CPU utilization information. Max CPU utilization since the last manual clear of the performance statistics using the C command.
Page 91
Total Access 850 System Manual > P YSTEM TILITY Activate the ping test and define the ping packet characteristics from this menu. > P > S YSTEM TILITY Activator to start and cancel a ping test. Only one ping session can be active at a time.
Page 92
DLP-13, Saving and Loading Text Configuration using Terminal Command Line, for further assistance.) • Debug and troubleshoot. This function would be carried out with the assistance of ADTRAN Technical Support. • Start and stop the fail-safe timer for the auto-config feature.
Page 93
Total Access 850 System Manual timeout (seconds) source (address or name) noNat Options may be entered in any order and may be truncated. Valid interface names are eth0, fdl0, ppp0, fr0, fr1, etc. Example usage: ping 10.0.0.5 r si 1500 so eth0 n This will ping with a repeat count of 10.
Page 95
Total Access 850 System Manual (T1) > C NTERFACES ONFIG Select the line build out for the T1 interface. These are attenuation settings. 0 dB is the strongest signal, and the other settings make the T1 transmit signal weaker. The setting of this field depends on whether the circuit is provisioned for DS1 by the telephone company.
Total Access 850 System Manual (T1) > S NTERFACES TATUS Displays the alarm history for the T1 interface. An asterisk in a field indicates that an alarm has occurred on the T1 interface since the last clear history. Refer to Interfaces (T1) > Status > Alarms > Current Alarms on page 96 for more details on listed alarm conditions.
Page 99
Total Access 850 System Manual (DSX) > S NTERFACES TATUS (Errored Second) - For ESF mode, an errored second is defined as a second with one or more Path Code Violations (PCVs), or one or more Out of Frame (OOF) defects, or one or more Controlled Slip events, or a detected AIS (blue alarm) defect.
NTERFACES ONFIG The Total Access 850 has the capability of auto negotiating the rate and duplex of the connected Ethernet link. Additionally, when this parameter is set to Negotiation is only available when using a 3rd Generation RCU with the Total Access 850 system.
Total Access 850 System Manual (FXS) NTERFACES View the FXS interface status and configure the FXS parameters from this menu. (FXS) > C NTERFACES ONFIG Configure the FXS mode, line impedance and Tandem parameters from this menu. (FXS) > C...
Page 105
Total Access 850 System Manual (FXS) > C NTERFACES ONFIG Causes the polarity of tip and ring to be reversed when the far-end answers. Can be enabled or disabled. Default is D ISABLE (FXS) > C NTERFACES ONFIG This parameter is used in conjunction with .
Page 107
Total Access 850 System Manual (FXO) NTERFACES View the FXO interface status and configure the FXO parameters from this menu. (FXO) > C NTERFACES ONFIG Configure the FXO mode, line impedance, and Tandem parameters from this menu. (FXO) > C...
Total Access 850 System Manual (FXO) > T > T NTERFACES Choices are given below. Default is IGITAL ETWORK ETWORK ETWORK 1004 H DCBM (FXO) > T > T NTERFACES This option indicates whether a test is in progress. (DSX-1 M...
Total Access 850 System Manual (UBR1TE M NTERFACES View the UBR1TE Module interface status and configure the UBR1TE Module parameters from this menu. (UBR1TE) > C NTERFACES Configures the UBR1TE interface format and code from this menu. (UBR1TE) > C...
Page 113
Total Access 850 System Manual (UBR1TE) > C NTERFACE ONFIG DC sealing current is only applicable if the mode is Adjacent-to-Customer applications. Default is (UBR1TE) > S NTERFACE TATUS View the interface status information for the UBR1TE Module. (UBR1TE) > S...
Page 114
These tests are only valid for the Adjacent-to-Customer circuit position. Use ADDR2 to test an ADTRAN U-Repeater deployed from the UBR1TE. A point-to-point (straight-away) test initiated toward the T1 carrier interface. The internal 2047 test pattern generator is used to verify the performance of the bearer channel.
Page 115
Total Access 850 System Manual 1. Minimum of 35 transition in progress (TIP) bytes (*0111010). 2. Minimum of 35 LSC bytes: OCU (*1010101), CSU (*0110001). 3. Minimum of 100 loopback enable (LBE) bytes (*1010110). 4. Minimum of 32 far-end voice (FEV) bytes (*1011010).
ROTOCOL Use the L2 protocol menu to select the L2 protocol, configure the protocol specific parameters and view the status as shown in Figure 8. The following menus are for Total Access 850 systems using T1 TDM firmware. For convenience, the following heading notations identify the type of firmware and L2 protocol configured in the Total Access 850 system: L2 Protocol (T1 TDM –...
Total Access 850 System Manual L2 P (T1 TDM F ROTOCOL Configure the L2 Protocol parameters and view the status of the T1 interface using items from this menu. L2 P (T1 TDM – T1) > P ROTOCOL Configure the L2 protocol mode. Choices are the interface for Point-to-Point Protocol signaling on Layer 2.
Page 119
(T1 TDM–T1–PPP) > C ROTOCOL When enabled, this option enables the Total Access 850 to send the system identification code in response to a configure acknowledgement from the peer equipment. For most peer routers this option should be configured as .
Page 120
Number of packets transmitted on the T1 interface L2 P (T1 TDM–T1–PPP) > S ROTOCOL Clears the PPP stats (returning the counters to 0) for the T1 interface. Total Access 850 System Manual > R TATUS > T TATUS YTES >...
Page 121
Total Access 850 System Manual L2 P (T1 TDM F ROTOCOL Configure the parameters and view the status of the T1 interface using Frame Relay protocol L2 P ROTOCOL from this menu. L2 P (T1 TDM–T1–FRE) > C ROTOCOL Configure the parameters for the T1 interface using the Frame Relay protocol.
Page 123
Total Access 850 System Manual L2 P (T1 TDM–T1–FRE) > S ROTOCOL View the Frame Relay statistics on the WAN port. L2 P (T1 TDM–T1–FRE) > S ROTOCOL Integer used for identifying DLCIs on an interface. A single DLCI will always be port index 0. Subsequent DLCIs will have incrementing port indices.
Page 125
Total Access 850 System Manual L2 P (T1 TDM–T1–FRE) > S ROTOCOL Number of Frame Relay bytes that have been received via this DLCI. L2 P (T1 TDM–T1–FRE) > S ROTOCOL Number of packets received on this DLCI with the Discharge Eligible (DE) bit set.
Page 127
Total Access 850 System Manual L2 P (T1 TDM–T1–A ROTOCOL This field represents the state of the auto detect/configuration function. The possible state are: ETECTING ROTOCOL ONFIRMING ONFIRMED ONFIRMING ONFIRMED L2 P (T1 TDM–T1–A ROTOCOL Number of packets transmitted out of the WAN port.
Page 128
L2 P ROTOCOL view the status as shown in Figure 8. The following menus are for Total Access 850 systems using T1 ATM firmware. For convenience, the following heading notations identify the type of firmware and L2 protocol configured in the Total Access 850 system: L2 Protocol (T1 ATM –...
Page 129
Total Access 850 System Manual L2 P (T1 ATM F ROTOCOL Configure the parameters and view the status of the T1 interface using items from this menu. L2 P ROTOCOL L2 P (T1 ATM – T1) > P ROTOCOL Configure the mode.
Page 131
OUTER Identifies how the data will be transferred through the Total Access 850 system. The following choices are available: IP (def) – All IP data for this PVC is routed through the Total Access 850 integral OUTE router. – All data for this PVC is bridged through the Total Access 850 system.
Page 132
Specifies the method the Total Access 850 uses to obtain PPP authentication from the peer. There are four possible selections: ETHOD Specifies the method the Total Access 850 uses to authenticate the PPP peer. There are four possible selections: Configure the PPP specific parameters such as...
Page 133
Total Access 850 System Manual ONFIG This value is the number of unanswered configuration-requests that should be transmitted before resetting PPP negotiations. the possible values are IMER This value is the number of seconds to wait between unanswered configuration-requests. The possible values are...
Page 135
The Call Control setting is used to configure the correct Voice Gateway protocol for voice signaling control between the Total Access 850 and the configured Gateway. The setting must be configured correctly before the voice circuits will work correctly. The Total Access 850 supports Jetstream, Coppercom, Tollbridge, and LES-CAS.
Page 136
View the ATM PVC statistics from this menu. L2 P (T1 ATM–T1–ATM) > S ROTOCOL Displays the index number in the PVC Status menu. Total Access 850 System Manual > ATM S TATUS TATUS Number of cells transmitted over the ATM link.
Page 137
Total Access 850 System Manual L2 P (T1 ATM–T1–ATM) > S ROTOCOL The T1 ATM[0.0] NTERFACE read-only field. L2 P (T1 ATM–T1–ATM) > S ROTOCOL Shows the statistics of ATM Adaptation Layer frames. PDU S TX D YTES TX F...
Page 138
Indicates that the Total Access 850 received voice packets that were out of sequence according to the voice sequencing bits. The Total Access 850 does not drop these packets, but the error is logged because invalid sequence numbers were received.
Page 139
TATS Selecting this menu options will show real-time indication status of each voice port on the Total Access 850. On a per port basis, the user can determine which ports are active/inactive as well as view other statistics like The Echo Canceller module ADPCM functionality automatically shifts ON/OFF when fax or modem calls are placed.
Page 140
Voice Gateway protocol for voice signaling ONTROL control between the Total Access 850 and the configured Gateway. The Call Control setting must be configured correctly before the voice circuits will work correctly. The Total Access 850 supports...
ROTOCOL interface for network interworking and should be used for Frame Relay over ATM applications. Selecting configures the interface for service interworking allowing the Total Access 850 to make the FRF8 translation between Frame Relay signaling on the V35 interface and ATM protocols on the network interface.
Page 143
NTERFACES Digital trunk channel ID's are bits used to identify voice calls being carried within ATM cells. Some gateways do not support higher channel IDs, therefore the Total Access 850 supports CIDs from 16 or 65. The default is DSX CID...
Total Access 850 System Manual L2 P (ALL–ETH–802.3) > S ROTOCOL Number of packets received in error and dropped. L2 P (ALL–ETH–802.3) > S ROTOCOL Number of packets detected with CRC errors. L2 P (ALL–ETH–802.3]) > S ROTOCOL Number of collisions which occurred during reception.
Page 147
Total Access 850 System Manual Section 4 User Interface Guide > S > B > TTL RIDGE TATUS RIDGE ABLE Time to Live (TTL) is the number of seconds until the address is removed from the table. This is a read only field.
Page 149
Total Access 850 System Manual > C > I OUTER ONFIG NTERFACES Configure the Ethernet addressing, RIP, and Proxy ARP from this menu. RIMARY This is used to setup the IP addresses for the LAN on the unit. IP A DDRESS The IP address assigned to the unit's Ethernet port is set here.
Page 153
(Read only) This menu appears when the and displays the name of the specified protocol number (if the name is known by the Total Access 850). For example, entering a value of 47 in the field will cause the 64203376L1-1B...
Page 155
Total Access 850 System Manual RIVATE Select (default) or a private destination port associated with this entry can be specified to provide more control over certain types of traffic. Leave configured as cover all port types. RIVATE This menu appears when the the user to enter the port number that replaces the public port number during the translation of incoming packets.
VERFLOW OUNT The number of overflow reached, the Total Access 850 will not add new translations, but continues to keep a count of any new translation requests it cannot accommodate. Use this menu to enable RIP on this interface. ERSION Enables or disables RIP and specifies the RIP protocol.
Total Access 850 System Manual ETHOD Specifies the way the RIP protocol sends out its advertisements. The following options are available: PLIT ORIZON (Default) Only routes not learned from this circuit are advertised. OISON EVERSE All routes are advertised, but the routes learned from this point are “poisoned” with an infinite metric.
Page 159
Total Access 850 System Manual ETWORK DDRESS Defines the network address for the configured address pool (for example, 172.24.0.0). The ETWORK DDRESS network for the configured pool. ETWORK Defines the network mask associated with the network address for the configured address pool (for example, 255.255.0.0).
Page 160
OUTER ONFIG Defines any IP address (or range of addresses) that should not be used the Total Access 850 DHCP server when making IP assignments to hosts on the network. Displays the index number of the listed IP address exclusion ranges. Multiple address exclusions are valid, and all will be listed in sequential order.
Total Access 850 System Manual > C > UDP R OUTER ONFIG This menu configures the unit to act as a UDP relay agent for applications requiring a response from UDP hosts that are not on the same network segment as their clients.
Total Access 850 System Manual • • ICMP • • All of these statistics are taken from the MIB-II variables in RFC 1156. To clear the accumulated statistics, press the <E > key on NTER LEAR > S > IP S...
Page 165
Total Access 850 System Manual UCCESSFUL RAGMENTS The number of IP datagrams that have been successfully fragmented at this unit. AILED RAGMENTS The number of IP datagrams that have been discarded because they needed to be fragmented at this unit but could not be e.g., because their “Don't Fragment” flag was set.
Page 167
Total Access 850 System Manual ICMP P ARAMETER ROBLEM The number of ICMP Parameter Problem messages sent. ICMP S OURCE UENCH The number of ICMP Source Quench messages sent. ICMP R EDIRECT The number of ICMP Redirect messages sent. ICMP E EQUEST The number of ICMP Echo (request) messages sent.
Page 169
Total Access 850 System Manual TCP C ONNECTIONS The limit on the total number of maximum number of connections is dynamic, this object should contain the value -1. TCP C CTIVE ONNECTIONS The number of times connections have made a direct transition to the state.
Page 173
Total Access 850 System Manual Bits in the MAC destination address used for comparison. Values are in hexadecimal format. Default 00:00:00:00:00:00 16-bit type field used for comparison. Values are in hexadecimal format. Default is Bits in the type field used for comparison. Values are in hexadecimal format. Default is >...
Page 175
Total Access 850 System Manual IP destination port number used for comparison. Value is in decimal format. Range: Default is Type of comparison that is performed. Default is means ports equal to means port not equal to means port greater than >...
Total Access 850 System Manual The next operation to use to combine with the next filter in the list (default is OUNT Displays the number of packets that match the criteria for the defined filter. UT TO The packets which come from the unit to the WAN can be filtered in three ways:...
Page 179
Total Access 850 System Manual > R ECURITY ADIUS ERVER This is the number of times the unit should send a request packet tho the response before giving up. If the number of attempts to communicate with the primary server is equal to the retry count, the second server (if defined) is tried.
Page 181
Total Access 850 System Manual Section 4 User Interface Guide DS0 M > E 1 > RBS Robbed Bit Signaling. Default is . Once a and port are assigned, this will automatically change to SLOT . The unit automatically assigns where is not an option.
Appendix A. Configuring the Unit for Routing Initial Setup It is best to configure Total Access 850 TDM applications by following the order of the top-level menus. For example, first configure the system parameters using the Next, configure the Layer 1 parameters using the configured, proceed to the Layer 2 setup using the data “routing”...
Page 183
Total Access 850 System Manual Most applications should not require a manual setup for the Ethernet interface. By default, the Ethernet interface is configured to auto-detect the data rate (as either 10 or 100 Mbps). The following steps disable the auto-negotiation parameter and manually configure the interface.
Page 184
RX M ETHOD other than N Total Access 850 supports various combinations of PAP, CHAP, and EAP for PPP authentication. Refer to L2 Protocol (T1 TDM–T1–PPP) > Config > Authentication on page 118 for more details. Left arrow out of the A press <E...
Page 186
CTIVE Select the desired A more details. Enter the Total Access 850 L for the selected virtual circuit. Enter the IP address for the next hop router in the F For NAT configuration, refer to Appendix C. RFC1483 Quick Start (IP Routing with NAT) on page 209.
DS0s (1 through 24) on the network T1 interface. At least one DS0 must be mapped to the to utilize the Total Access 850 for routing purposes. Scroll down to the DS0 that will be mapped. (Any DS0 can be mapped to the router.)
Appendix B. Configuring the Unit for Bridging Initial Setup It is best to configure Total Access 850 TDM applications by following the order of the top-level menus. For example, first configure the system parameters using the Next, configure the Layer 1 parameters using the configured, proceed to the Layer 2 setup using the data “routing”...
Page 189
Total Access 850 System Manual Most applications should not require a manual setup for the Ethernet interface. By default, the Ethernet interface is configured to auto-detect the data rate (as either 10 or 100 Mbps). The following steps disable the auto-negotiation parameter and manually configure the interface.
Page 190
UTHENTICATION the link is established. Default is T and RX M ETHOD other than N Total Access 850 supports various combinations of PAP, CHAP, and EAP for PPP authentication. Left arrow out of the A press <E NTER the PPP link. Refer to L2 Protocol (T1 TDM–T1–PPP) > Config on page 118 for more details.
Page 191
DS0s (1 through 24) on the network T1 interface. At least one DS0 must be mapped to the to utilize the Total Access 850 for routing purposes. Scroll down to the DS0 that will be mapped. (Any DS0 can be mapped to the router.)
Appendix C. Configuring the Unit for Voice Applications Initial Setup It is best to configure Total Access 850 TDM applications by following the order of the top-level menus. For example, first configure the system parameters using the Next, configure the Layer 1 parameters using the configured, proceed to the Layer 2 setup using the data “routing”...
Page 194
I GNORE Total Access 850 will follow the switch at all times; this is normal operation. If a time period has been selected, the Total Access 850 will remove battery for the specified time period OR as long as the switch requests battery removal, whichever is longer.
Page 195
Total Access 850 System Manual FXS Interface Setup Instructions (Continued) Press <E NTER port mode is set to T Set the C ONVERSION Set the S UPERVISION Be sure to set the T 2. Mapping the DS0s For more details on the configuration parameters discussed in this section, refer to the following pages:...
PBX, key system, etc.), as well as clear channel data to an external T1 router. Initial Setup It is best to configure Total Access 850 TDM applications by following the order of the top-level menus. For example, first configure the system parameters using the...
Page 197
Total Access 850 System Manual T1 Interface Setup Instructions (Continued) This line code must match the line code used by the other units in the network. Set the E QUALIZATION sufficient. Set the CSU L whether looping to this unit from another unit will be allowed.
Page 198
DS0 on the DSX-1 interface. For example, ISDN D channel signaling is normally carried on DS0 24. Unless the equipment connected to the Total Access 850 DSX-1 interface has been specifically programmed, it will expect a D channel on DS0 24. Map DS0 24 to Port 24 to provide the D channel in the appropriate timeslot.
CopperCom, and LES-CAS are popular Gateway types. To configure a Total Access 850 for use with the Voice Gateway, you need to know the VPI and VCI used on the ATM network to access the Gateway from this Total Access 850. You also need to know the format...
Section 4 User Interface Guide The following example provides step by step instructions for configuring the Total Access 850 T1 ATM system ( L2 P NTERFACES ROTOCOL parameters should be set according to your system need. Refer to System Info on page 73 and System Config on page 75 for more details.
Page 201
, the WITCH Total Access 850 will follow the switch at all times; this is normal operation. If a time period has been selected, the Total Access 850 will remove battery for the specified time period OR as long as the switch requests battery removal, whichever is longer.
Page 203
Total Access 850 System Manual Layer 2 Protocol Configuration – T1 Interface (Continued) Select S , and from the S ETUP and enter the VPI and VCI values for communicating with that ONTROL Gateway. For this application, C should be set appropriately for your network.
Page 204
To configure a Total Access 850 for IP routing, you need to know the VPI and VCI values for the data circuit on your network. You also need the IP address of the next hop router in the circuit.
Page 205
Total Access 850 System Manual Step From the main menu, select I Highlight the C Right arrow to select F This format must match the format used by the other units in the network. Set the L This line code must match the line code used by the other units in the network.
Page 208
Enter the appropriate VPI and VCI values. Select the desired A more details. Enter the Total Access 850 L for the selected virtual circuit. Enter the IP address for the next hop router in the F For NAT configuration, refer to Appendix C. RFC1483 Quick Start (IP Routing with NAT) on page 209.
Page 209
Total Access 850 System Manual Appendix C. RFC1483 Quick Start (IP Routing with NAT) To illustrate the use of NAT, consider the example from Appendix B. RFC1483 Quick Start (IP Routing) on page 204. To add NAT to the IP routing example, use the...
Page 210
Appendix D. RFC 1483 Quick Start (Bridging) Initial Setup It is best to configure Total Access 850 ATM applications by following the order of the top-level menus. For example, first configure the system parameters using the Next, configure the Layer 1 parameters using the configured, proceed to the Layer 2 setup using the data “routing”...
Page 211
Total Access 850 System Manual Most applications should not require a manual setup for the Ethernet interface. By default, the Ethernet interface is configured to auto-detect the data rate (as either 10 or 100 Mbps). The following steps disable the auto-negotiation parameter and manually configure the interface.
Total Access 850 is located on the faceplate of the RCU and is a DB-9 CRAFT connector. Access can also be made to the Total Access 850 from the back of the unit through the RJ-45 interface labeled , located on the back of the unit.
Page 216
Make connection to the PC or laptop as appropriate for your equipment. You are now ready to log in to the Total Access 850, as described in DLP-2, Logging in to the System. Total Access 850 System Manual ®...
DLP-2 Logging in to the System Introduction Once connected to the Total Access 850, you must login to the system to gain access to the management and provisioning functions. This DLP assumes you are connected to the Total Access 850 and provides specific steps for logging into the system.
Page 218
Login field indicates that a password must be entered. 2. Enter the password for the Total Access 850 at the Login field. There is no manufacturer’s default password; press <Enter> to enter the Total Access 850 menus.
77 for more details.) If the Total Access 850 is connected to an IP network for Telnet, TFTP, or SNMP management, there are several IP parameters which must be set for the unit to communicate with the network. These parameters are described in this DLP along with the procedures for setting them.
Page 220
Section 5 DLP-3 Perform the steps below in the order listed. 1. Connect the Total Access 850 unit to your VT100 system (details found in DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port). 2. Log in to the system.
Introduction When the Ethernet port is connected to a local area network (LAN), test steps must be performed on the Total Access 850 to ensure that the unit is communicating properly over the network. This procedure outlines those steps. Prerequisite Procedures Before beginning this procedure, the unit should be physically connected to the LAN and the provisioning tasks detailed in DLP-3, Setting IP Parameters for the Total Access 850, should be complete.
Page 222
If the Total Access 850 is connected to a hub or other network device that provides a carrier sense light for each port, verify that the carrier sense light for the port to which the Total Access 850 is connected is lit.
Page 223
Total Access 850 System Manual From the same computer used in the previous step, Telnet to the Total Access 850 and verify that the Telnet session is properly opened (see DLP-5, Connecting to the Total Access 850 Using Telnet). Once the Telnet session is established, press <...
77 for more details.) If the Total Access 850 is part of a management cluster connected to the local network, you may use a PC connected to the network to Telnet into the unit. This procedure details the steps which must be performed to Telnet into the unit.
Page 226
Section 5 DLP-5 Perform the steps below in the order listed. 1. Connect the computer to the Total Access 850 RCU faceplate CRAFT or rear CRAFT port (details in DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port).
Page 227
Total Access 850 System Manual 12. From a remote computer system connected to the LAN, Telnet to the Total Access 850. Refer to the documentation of the computer system if you are unsure how to perform a Telnet. Most computers running a networked version of Microsoft Windows™ or UNIX allow a Telnet to be performed by simply typing “Telnet <IP Address>”...
Page 228
Section 5 DLP-5 14. Enter the password assigned in step 6. After entering the correct password, the Total Access 850 main menu is displayed (see below): 15. After completing your configuration changes they are automatically saved (or manually save them by pressing <CTRL+W>), press <CTRL+L>...
Telnet access. All connections made through the maximum security rights. All menu items in the Total Access 850 are protected by passwords of varying security levels. By assigning different passwords to different security levels, the Total Access 850 System Administrator can control which users can view or change various menu items.
Page 230
You will have to type the new password again to confirm it. Passwords for the Total Access 850 system are case sensitive. There is no default password for a new user (i.e., you can configure a user as blank with no password). The current password displays as a series of asterisks (********).
Page 231
Total Access 850 System Manual 8. Determine the password level for the corresponding label. The Total Access 850 contains seven different password levels. The following chart gives a brief description of each level. Select Level... If you want the user to...
• A TFTP server accessible on the local network A TFTP server is provided as part of the ADTRAN Utilities software suite supplied with your shipment. To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.
Page 234
If you are not already connected to the unit’s procedure in DLP-5, Connecting to the Total Access 850 Using Telnet, to connect to the unit. 2. Log in to the unit using the read-write password (see DLP-2, Logging in to the System for details).
Page 235
TATUS message. Finally the T RANSFER The Total Access 850 will restart immediately and resume operation. After giving the unit sufficient time to reboot, the user may Telnet back into the unit and log in. 64203376L1-1B to indicate progress. The following table...
DLP-8 Updating the Firmware using XMODEM Introduction The Total Access 850 supports firmware updates using TFTP or XMODEM. (Use the Ethernet port and TFTP from a network server, or use XMODEM and the rear interface.) This procedure outlines the steps for a successful firmware upgrade using the rear...
Page 238
PC connected to the network to Telnet into the unit. By utilizing the Total Access 850 may be quickly upgraded using TFTP, provided there is a TFTP server on the local network. The Total Access 850 ships with ADTRAN Utilities software, which includes a TFTP server.
DLP-9 Saving the Current Configuration Using TFTP Introduction The Total Access 850 supports configuration transfers from the unit (via the to a TFTP server located on the network. This DLP provides the steps to follow for a successful configuration transfer using the...
Page 240
If you are not already connected to the unit’s procedure in DLP-5, Connecting to the Total Access 850 Using Telnet, to connect to the unit. 2. Log in to the unit using the read-write password (see DLP-2, Logging in to the System, for details).
DLP-10 Loading a Configuration Using TFTP Introduction The Total Access 850 supports configuration uploads from a unit (via the a TFTP server located on the network. This DLP provides the steps to follow for a successful configuration upload using the...
Page 242
If you are not already connected to the unit’s procedure in DLP-5, Connecting to the Total Access 850 Using Telnet, to connect to the unit. 2. Log in to the unit using the read-write password (see DLP-2, Logging in to the System, for details).
Page 243
Total Access 850 System Manual Section 5 DLP-10 10. When the upload process has successfully completed, I displays in the C URRENT RANSFER field and D displays in the P field. TATUS OWNLOAD OMPLETE REVIOUS RANSFER TATUS 11. After an appropriate length of time, the user may Telnet back into the unit.
DLP-11 Saving and Transferring a Current Configuration Using XMODEM Introduction The Total Access 850 supports configuration transfers from the unit via the rear interfaces using a VT100 terminal or terminal emulator (with XMODEM). This DLP provides the CRAFT steps for a successful configuration transfer using either the rear and XMODEM.
Page 246
Section 5 DLP-11 Perform the following steps in the order listed. 1. Connect to the Total Access 850 using the rear CRAFT (RJ-45) port on the back of the Total Access 850 or the RCU faceplate CRAFT (DB-9) interface. If you are not already connected to the unit’s rear with a VT100 compatible terminal or with a PC running VT100 emulation software, follow the procedure in DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port.
DLP-12 Loading a Configuration Using XMODEM Introduction The Total Access 850 supports configuration uploads from a unit via the rear interface using a VT100 terminal or terminal emulator (with XMODEM). This DLP provides the CRAFT steps for a successful configuration upload using either the rear XMODEM protocol.
Page 248
Section 5 DLP-12 Perform the following steps in the order listed. 1. Connect to the Total Access 850 using the rear CRAFT (RJ-45) or the RCU faceplate CRAFT (DB-9) interface located on the front of the RCU. If you are not already connected to the unit’s rear with a VT100 compatible terminal or with a PC running VT100 emulation software, follow the procedure in DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port.
Command Line Introduction The Total Access 850 RCU has the ability to download a text file which contains the configuration of the entire unit. This configuration may then be altered in a text editor and uploaded to any Total Access 850 RCU.
Page 250
Section 5 DLP-13 Total Access 850 System Manual Perform the steps below in the order listed. Saving the router's configuration 1. Establish a connection to the router with the VT100 terminal software either through the rear CRAFT or RCU faceplate CRAFT port.
Page 251
Loading a configuration into the router The following steps explains the process for uploading the text file back into the Total Access 850 RCU. These text files can be the entire configuration, or just partial commands that affect specific configuration changes.
To prevent electrical shock, do not install equipment in a wet location or during a lightning storm. Prerequisite Procedures Obtain the A.04 firmware and the A.03.90 (Transition Build) firmware from the ADTRAN website (http://www.ADTRAN.com). For the Total Access 850 units, select TOTAL ACCESS PRODUCTS >...
The Total Access 850 Syslog Utility records various message types at settable threshold levels to an external Syslog server (software supplied with the Total Access 850 system ADTRAN Utilities). Prerequisite Procedures This procedure assumes that the Total Access 850 unit is connected to an IP network and is powered up. Tools and Materials Required •...
Page 258
0 through L OCAL specified in the Total Access 850. The Syslog program must be open on your PC in order for it to record Total Access 850 information. The Syslog files can be viewed through the Syslog window, and they are also available under the ADTRAN Utilities Folder named L through 7.
Page 259
Total Access 850 System Manual Additional Syslog Features: • feature allows all Syslog messages to be prefiltered by ONITOR before displaying these messages to the user and logging the message to the pre-designated monitor log file. Various filter options may be defined by selecting window.
Alarm connections alert the user when a selected alarm condition exists. Pressing the Alarm Cut-Off ) switch on the front panel of the Total Access 850 PSU clears the alarm. This procedure details the steps which must be performed to use the Total Access 850 alarm connections and the This procedure should be performed at installation on each Total Access 850 shelf that is wired out to external office alarm equipment.
Page 262
1. Backplane alarm connections (P5) are labeled as shown in the table below and illustrated in the figure. -48 ALM MJVR You will have to remove the cover to access the contacts. Refer to the Total Access 850 rear view illustration on the next page. P3 Wire-Wrap Connections...
Page 263
3. In a carrier alarm condition such as a Red, Yellow, or Blue (unframed all 1s), various alarm contacts in the PSU close. 4. Carrier alarm conditions cause the Total Access 850 to initiate trunk processing. The following chain of events then occur: •...
Dual T1 Map to be configured successfully. These steps are described in this DLP. Prerequisite Procedures This procedure assumes that the user has access to the Total Access 850 system menus. Refer to DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port, for details on making a terminal connection to the Total Access 850.
Page 266
Section 5 DLP-17 Perform the steps below in the order listed. 1. Connect the Total Access 850 unit to your VT100 system (details found in DLP-1, Connecting a VT100 Terminal or PC to the CRAFT Port). 2. Log in to the system with maximum rights (details are in DLP-2, Logging in to the System).
Page 267
Total Access 850 System Manual Section 5 DLP-17 5. Edit the Primary T1 Map by pressing <Enter> on E T1 M [+].The following screen appears. Figure 2. Primary T1 Map The T1 Map can be mapped to the internal router or other available access module.
Page 268
Section 5 DLP-17 Total Access 850 System Manual 6. Edit the Secondary T1 Map (DSX Map) by pressing <Enter> on E DSX M [+]. The following screen appears. Figure 3. DSX Map The DSX Map can be mapped to the FXS and FXO access modules only.
This section provides instructions for configuring and using the ADTRAN Utilities software programs including Telnet, VT100, Syslog, and TFTP. ADTRAN delivers several PC software utilities with the Total Access 850. These utilities are located on the CD-ROM that came with your shipment. The utilities make it easier to interface with the terminal menu and transfer configuration files to and from TFTP servers.
Total Access 850 System Manual Session Menu Click on to open the Telnet session. ESSION Connect Opens dialog box for setting parameters for a Telnet session. Also lets entry, and NTRY stored entries. When the parameters are set, click to make the connection. Click ONNECT to end the session.
File Sends screen options data to a file in the format options listed below: Start Cfg Capture Used with the ADTRAN product line to start sending the scrolling screen capture to a file storage location. Stop Cfg Capture Used with the ADTRAN product line to stop sending the scrolling screen capture to a file storage location.
Displays version and owner information. VT100 UTILITY Use the VT100 to configure an Total Access 850 which is directly connected to a PC. The VT100 display is almost identical to the Telnet display. For a detailed description of how to work within the terminal menu, refer to Navigating the Terminal Menu on page 67 (in the User Interface Guide section of this manual).
Provides the options RANSMIT Transmit Wakeup Provides a control sequence that puts the Total Access 850 Control Port online in terminal mode. Transmit Refresh Provides a control sequence to refresh the screen automatically when connecting. (This is the default setting for the Total Access 850.)
Figure 3 for the menu tree). You can install this program on a PC running any version of Microsoft Windows. The configuration of an Total Access 850 can be saved offline as a backup file. The saved file may also be used to send the same configuration to multiple Total Access 850 units. Transfer configuration files using the TFTP protocol (a TCP/IP user protocol) via the Ethernet port.
Only one configuration transfer session (upload or download) may be active at a time. The TCP/IP parameters are not saved or overwritten as part of an Total Access 850 unit’s transferred configuration to allow sending identical configurations to multiple units. When you start this program, a port is automatically opened.
Total Access 850 System Manual Help Provides online help and version information. Contents Opens online help. About Displays version and owner information. STATUS FIELD This field displays general information about port and transfer status. This field is read-only. The unlabeled field in the center of the screen displays prompts about the status of active transfers, such as bytes transferred and received.
Section 7 MIBs For this section, TDM units refers to Total Access 850 units running A.04 firmware or later. ATM units refers to Total Access 850 units running C.02 firmware or previous. The TDM units support SNMP Version 2. The ATM units support SNMP Version 1.
Total Access 850 System Manual MIB COMPILATION ORDER FOR TDM UNITS IANAifType-MIB PerfHist-TC-MIB SNMPv2-MIB (if not included with SNMP manager) IF-MIB IP-MIB IP-FORWARD-MIB FRAME-RELAY-DTE-MIB DS1-MIB DS0-MIB DS0BUNDLE-MIB EtherLike-MIB CIRCUIT-IF-MIB ADTRAN-MIB ADTRAN-IADSYS-MIB ADTRAN-IADROUTER-MIB TRAPS SUPPORTED BY TDM UNITS From RFC1215-MIB: From ADTRAN-IADSYS-MIB:...
Adtran.mib adtartr_trap.mib RFC1155-SMI, RFC1212-MIB, and RFC1215-MIB are also needed and should come standard with any SNMP Management software. All ATM MIBs are SNMPv1. Total Access 850 System Manual adIadDs1CRC - 1003217 adIadDs1LCV - 1003218 adIadDs1SLP - 1003219 adIadVoiceTestStatusActive - 1003401...
Total Access 850 System Manual MIB COMPILATION ORDER FOR ATM UNITS RFC1213-MIB RFC1406-MIB RFC1695-MIB ADTRAN-MIB ADTRAN-ADTARTR-TRAP-MIB TRAPS SUPPORTED BY ATM UNITS From ADTARTR_TRAP MIB: MIB VARIABLES SUPPORTED BY ATM UNITS ATM units do not support write access for SNMP (except for sysName, sysLocation, and sysContact).