:INTEGrate?
Function
Queries all settings related to the integration.
Syntax
:INTEGrate?
Example
• Example during normal integration mode with
individual element integration set to OFF
:INTEGRATE? -> :INTEGRATE:
MODE NORMAL;CURRENT:ELEMENT1 RMS;
ELEMENT2 RMS;ELEMENT3 RMS;
ELEMENT4 RMS;:INTEGRATE:ACAL 0;
INDEPENDENT 0;TIMER1 1,0,0
• Example during real-time normal integration
mode with individual element integration set
to OFF
:INTEGRATE? -> :INTEGRATE:
MODE RNORMAL;CURRENT:
ELEMENT1 RMS;ELEMENT2 RMS;
ELEMENT3 RMS;ELEMENT4 RMS;:
INTEGRATE:ACAL 0;INDEPENDENT 0;
TIMER1 1,0,0;RTIME1:
START 2001,1,1,0,0,0;
END 2001,1,1,1,0,0
• Example during normal integration mode with
individual power measurement element
integration set to ON
:INTEGRATE? -> :INTEGRATE:
MODE NORMAL;CURRENT:ELEMENT1 RMS;
ELEMENT2 RMS;ELEMENT3 RMS;
ELEMENT4 RMS;:INTEGRATE:ACAL 0;
INDEPENDENT 1;TIMER1 1,0,0;
TIMER2 1,0,0;TIMER3 1,0,0;
TIMER4 1,0,0
• Example during real-time normal integration
mode with individual power measurement
element integration set to ON
:INTEGRATE? -> :INTEGRATE:
MODE RNORMAL;CURRENT:
ELEMENT1 RMS;ELEMENT2 RMS;
ELEMENT3 RMS;ELEMENT4 RMS;:
INTEGRATE:ACAL 0;INDEPENDENT 1;
TIMER1 1,0,0;TIMER2 1,0,0;
TIMER3 1,0,0;TIMER4 1,0,0;
RTIME1:START 2001,1,1,0,0,0;
END 2001,1,1,1,0,0;:INTEGRATE:
RTIME2:START 2001,1,1,0,0,0;
END 2001,1,1,1,0,0;:INTEGRATE:
RTIME3:START 2001,1,1,0,0,0;
END 2001,1,1,1,0,0;:INTEGRATE:
RTIME4:START 2001,1,1,0,0,0;
END 2001,1,1,1,0,0
:INTEGrate:ACAL
Function
Turns ON/OFF the auto calibration or queries
the current setting.
Syntax
:INTEGrate:ACAL {<Boolean>}
:INTEGrate:ACAL?
Example
:INTEGRATE:ACAL OFF
:INTEGRATE:ACAL? -> :INTEGRATE:
ACAL 0
IM 760151-17E
:INTEGrate:CURRent?
Function
Queries the current mode of the current
integration of all power measurement elements.
Syntax
:INTEGrate:CURRent?
Example
:INTEGRATE:CURRENT? -> :INTEGRATE:
CURRENT:ELEMENT1 RMS;ELEMENT2 RMS;
ELEMENT3 RMS;ELEMENT4 RMS
:INTEGrate:CURRent[:ALL]
Function
Collectively sets the current mode of the current
integration of all power measurement elements.
Syntax
:INTEGrate:CURRent[:ALL] {RMS|MEAN|
DC|AC}
Example
:INTEGRATE:CURRENT:ALL RMS
:INTEGrate:CURRent:ELEMent<x>
Function
Sets the current mode of the current integration
of the power measurement element or queries
the current setting.
Syntax
:INTEGrate:CURRent:ELEMent<x> {RMS|
MEAN|DC|AC}
:INTEGrate:CURRent:ELEMent<x>?
<x> = 1 to 4 (power measurement element)
Example
:INTEGRATE:CURRENT:ELEMENT1 RMS
:INTEGRATE:CURRENT:ELEMENT1? ->
:INTEGRATE:CURRENT:ELEMENT1 RMS
Description The WT1600FC operates according to the
current mode of the current integration of each
element regardless of whether the individual
power measurement element integration
(:INTEGrate:INDependent) is ON.
:INTEGrate:INDependent
Function
Turns ON/OFF the individual power
measurement element integration or queries the
current setting.
Syntax
:INTEGrate:INDependent {<Boolean>}
:INTEGrate:INDependent?
Example
:INTEGRATE:INDEPENDENT OFF
:INTEGRATE:INDEPENDENT? ->
:INTEGRATE:INDEPENDENT 0
:INTEGrate:MODE
Function
Sets the integration mode or queries the current
setting.
Syntax
:INTEGrate:MODE {NORMal|CONTinuous|
RNORmal|RCONtinuous}
:INTEGrate:MODE?
NORMal = Normal integration mode
CONTinuous = Continuous integration mode
RNORmal = Real-time normal integration mode
RCONtinuous = Real-time continuous
integration mode
Example
:INTEGRATE:MODE NORMAL
:INTEGRATE:MODE? -> :INTEGRATE:
MODE NORMAL
5.11 INTEGrate Group