YOKOGAWA WT1600FC User Manual page 78

Impedance meter communication interface
Table of Contents

Advertisement

5.9 IMPedance Group
:IMPedance:DCControl:DETaile:HOLD
Function
Sets the action taken by the WT1600FC
(handling of the control signal to the DC
electronic load device) when hold is activated or
queries the current setting.
Syntax
:IMPedance:DCControl:DETaile:
HOLD {NORMal|OFF}
:IMPedance:DCControl:DETaile:HOLD?
Example
:IMPEDANCE:DCCONTROL:DETAILE:
HOLD NORMAL
:IMPEDANCE:DCCONTROL:DETAILE:HOLD?
-> :IMPEDANCE:DCCONTROL:DETAILE:
HOLD NORMAL
:IMPedance:DCControl:DETaile:LIMit
Function
Sets the range of the DC load current or queries
the current setting.
Syntax
:IMPedance:DCControl:DETaile:
LIMit {<NRf>,<NRf>}
:IMPedance:DCControl:DETaile:LIMit?
<NRf> = –1000.000 to 1000.000(A)
Example
:IMPEDANCE:DCCONTROL:DETAILE:
LIMIT 1000,-1000
:IMPEDANCE:DCCONTROL:DETAILE:LIMIT?
-> :IMPEDANCE:DCCONTROL:DETAILE:
LIMIT 1000.000,-1000.000
Description Set the upper limit and then the lower limit.
:IMPedance:DCControl:DETaile:RATio
Function
Sets the current value per volt of the control
signal to the DC electronic load device or
queries the current setting.
Syntax
:IMPedance:DCControl:DETaile:
RATio {<NRf>}
:IMPedance:DCControl:DETaile:RATio?
<NRf> = 0.001 to 1000.000
Example
:IMPEDANCE:DCCONTROL:DETAILE:
RATIO 1
:IMPEDANCE:DCCONTROL:DETAILE:RATIO?
-> :IMPEDANCE:DCCONTROL:DETAILE:
RATIO 1.000
:IMPedance:DCControl:OFFSet
Function
Sets the current value of the DC load current or
queries the current setting.
Syntax
:IMPedance:DCControl:OFFSet {<NRf>}
:IMPedance:DCControl:OFFSet?
<NRf> = –1000.000 to 1000.000(A)
Example
:IMPEDANCE:DCCONTROL:OFFSET 0
:IMPEDANCE:DCCONTROL:OFFSET? ->
:IMPEDANCE:DCCONTROL:OFFSET 0.000
5-42
:IMPedance:DCControl:OUTPut
Function
Turns ON/OFF the DC load current or queries
the current setting.
Syntax
:IMPedance:DCControl:
OUTPut {<Boolean>}
:IMPedance:DCControl:OUTPut?
Example
:IMPEDANCE:DCCONTROL:OUTPUT ON
:IMPEDANCE:DCCONTROL:OUTPUT? ->
:IMPEDANCE:DCCONTROL:OUTPUT 1
:IMPedance:MEASure?
Function
Queries all settings related to impedance
measurements.
Syntax
:IMPedance:MEASure?
Example
:IMPEDANCE:MEASURE? ->
:IMPEDANCE:MEASURE:TYPE STABLE
:IMPedance:MEASure:ANALysis?
Function
Sets the type of impedance measurement mode
or queries the current setting.
Syntax
:IMPedance:MEASure:ANALysis?
Example
:IMPEDANCE:MEASURE:ANALYSIS? ->
NORMAL
Description • The details of the response are as follows:
NORMal: Normal mode
WIDE: Wideband mode
• For the details on the mode, see the
WT1600FC User's Manual (IM760151-01E).
:IMPedance:MEASure:ARRay?
Function
Queries the array information of the loaded
pattern file.
Syntax
:IMPedance:MEASure:ARRay? {<NRf>}
<NRf> = 1 to 100 (array number)
Example
:IMPEDANCE:MEASURE:ARRAY? 1 -> 1
:IMPEDANCE:MEASURE:ARRAY? ->
1,2,5,10,-1,-1,...
Description • Outputs the order of the specified array
number.
• If the parameter is omitted, the orders of array
numbers 1 to 100 are output sequentially
(comma separated).
:IMPedance:MEASure:TYPE
Function
Sets the FFT window width of impedance
measurements or queries the current setting.
Syntax
:IMPedance:MEASure:TYPE {STABle|
MIDDle|FAST}
:IMPedance:MEASure:TYPE?
Example
:IMPEDANCE:MEASURE:TYPE STABLE
:IMPEDANCE:MEASURE:TYPE? ->
:IMPEDANCE:MEASURE:TYPE STABLE