YOKOGAWA WT1600FC User Manual page 90

Impedance meter communication interface
Table of Contents

Advertisement

5.10 INPut Group
[:INPut]:VOLTage:AUTO:ELEMent<x>
Function
Turns ON/OFF the voltage auto range of the
power measurement element or queries the
current setting.
Syntax
[:INPut]:VOLTage:AUTO:
ELEMent<x> {<Boolean>}
[:INPut]:VOLTage:AUTO:ELEMent<x>?
<x> = 1 to 4 (power measurement element)
Example
:INPUT:VOLTAGE:AUTO:ELEMENT1 ON
:INPUT:VOLTAGE:AUTO:ELEMENT1? ->
:INPUT:VOLTAGE:AUTO:ELEMENT1 1
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
[:INPut]:VOLTage:MRANge? (Measured
RANge)
Function
Queries the voltage range with respect to the
present measured value.
Syntax
[:INPut]:VOLTage:MRANge? {<NRf>}
<NRf> = 1 to 4 (power measurement element)
Example
:INPUT:VOLTAGE:MRANGE? 1 ->
1.0000E+03
:INPUT:VOLTAGE:MRANGE? ->
1.0000E+03,1.0000E+03,
1.0000E+03,1.0000E+03
Description • Returns the measurement range displayed on
the right side of the screen. The present
measurement range can be retrieved even
when auto range is ON.
• If the parameter is omitted, the measurement
ranges of all built-in power measurement
elements are output in order starting with
element 1.
• This command is invalid on models that are
only equipped with impedance measurement
elements, since the mode is fixed to
impedance measurement.
[:INPut]:VOLTage:RANGe?
Function
Queries the voltage ranges of all power
measurement elements.
Syntax
[:INPut]:VOLTage:RANGe?
Example
:INPUT:VOLTAGE:RANGE? -> :INPUT:
VOLTAGE:RANGE:ELEMENT1 1.0000E+03;
ELEMENT2 1.0000E+03;
ELEMENT3 1.0000E+03;
ELEMENT4 1.0000E+03
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
5-54
[:INPut]:VOLTage:RANGe[:ALL]
Function
Collectively sets the voltage range of all power
measurement elements.
Syntax
[:INPut]:VOLTage:RANGe[:ALL]
{<Voltage>|AUTO}
<Voltage> = 1.5, 3, 6, 10, 15, 30, 60, 100,
150, 300, 600, or 1000 (V)
AUTO = Auto range
Example
:INPUT:VOLTAGE:RANGE:ALL 1000V
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
[:INPut]:VOLTage:RANGe:ELEMent<x>
Function
Sets the voltage range of the power
measurement element or queries the current
setting.
Syntax
[:INPut]:VOLTage:RANGe:
ELEMent<x> {<Voltage>|AUTO}
[:INPut]:VOLTage:RANGe:ELEMent<x>?
<x> = 1 to 4 (power measurement element)
<Voltage> = 1.5, 3, 6, 10, 15, 30, 60, 100,
150, 300, 600, or 1000 (V)
AUTO = Auto range
Example
:INPUT:VOLTAGE:RANGE:ELEMENT1 1000V
:INPUT:VOLTAGE:RANGE:ELEMENT1? ->
:INPUT:VOLTAGE:RANGE:
ELEMENT1 1.0000E+03
Description • Specifying "Auto" with this command is
equivalent to setting
"[:INPut]:VOLTage:AUTO:
ELEMent<x>" to "ON."
• This command is invalid on models that are
only equipped with impedance measurement
elements, since the mode is fixed to
impedance measurement.
IM 760151-17E

Advertisement

Table of Contents
loading

Table of Contents