5.4 DISPlay Group
:DISPlay:WAVE:ALL
Function
Collectively turns ON/OFF all waveform
displays.
Syntax
:DISPlay:WAVE:ALL {<Boolean>}
Example
:DISPLAY:WAVE:ALL ON
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
:DISPlay:WAVE:FORMat
Function
Sets the display format of the waveform or
queries the current setting.
Syntax
:DISPlay:WAVE:FORMat {SINGle|DUAL|
TRIad|QUAD}
:DISPlay:WAVE:FORMat?
Example
:DISPLAY:WAVE:FORMAT SINGLE
:DISPLAY:WAVE:FORMAT? -> :DISPLAY:
WAVE:FORMAT SINGLE
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
:DISPlay:WAVE:GRATicule
Function
Sets the graticule (grid) type or queries the
current setting.
Syntax
:DISPlay:WAVE:GRATicule {GRID|
FRAMe|CROSshair}
:DISPlay:WAVE:GRATicule?
Example
:DISPLAY:WAVE:GRATICULE GRID
:DISPLAY:WAVE:GRATICULE? ->
:DISPLAY:WAVE:GRATICULE GRID
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
:DISPlay:WAVE:INTerpolate
Function
Sets the interpolation method of the waveform
or queries the current setting.
Syntax
:DISPlay:WAVE:INTerpolate {OFF|
LINE}
:DISPlay:WAVE:INTerpolate?
Example
:DISPLAY:WAVE:INTERPOLATE LINE
:DISPLAY:WAVE:INTERPOLATE? ->
:DISPLAY:WAVE:INTERPOLATE LINE
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
5-26
:DISPlay:WAVE:MAPPing?
Function
Queries all settings related to the waveform
mapping to the split screen.
Syntax
:DISPlay:WAVE:MAPPing?
Example
:DISPLAY:WAVE:MAPPING? -> :DISPLAY:
WAVE:MAPPING:MODE USER;U1 0;U2 1;
U3 2;U4 3;I1 0;I2 1;I3 2;I4 3
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
:DISPlay:WAVE:MAPPing[:MODE]
Function
Sets the waveform mapping method for the split
screen or queries the current setting.
Syntax
:DISPlay:WAVE:MAPPing[:MODE] {AUTO|
FIXed|USER}
:DISPlay:WAVE:MAPPing:MODE?
Example
:DISPLAY:WAVE:MAPPING:MODE AUTO
:DISPLAY:WAVE:MAPPING:MODE? ->
:DISPLAY:WAVE:MAPPING:MODE AUTO
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
:DISPlay:WAVE:MAPPing:{U<x>|I<x>}
Function
Sets the mapping of the {voltage|current}
waveform to the split screen or queries the
current setting.
Syntax
:DISPlay:WAVE:MAPPing:{U<x>|I<x>}
{<NRf>}
:DISPlay:WAVE:MAPPing:{U<x>|I<x>}?
<x> = 1 to 4 (power measurement element)
<NRf> = 0 to 3
Example
:DISPLAY:WAVE:MAPPING:U1 0
:DISPLAY:WAVE:MAPPING:U1? ->
:DISPLAY:WAVE:MAPPING:U1 0
Description • This command is valid when the waveform
mapping method (:DISPlay:WAVE:
MAPPing[:MODE]) is set to "USER."
• This command is invalid on models that are
only equipped with impedance measurement
elements, since the mode is fixed to
impedance measurement.