YOKOGAWA WT1600FC User Manual page 44

Impedance meter communication interface
Table of Contents

Advertisement

5.1 Command List
Command
:MEASure:FUNCtion<x>?
:MEASure:FUNCtion<x>:EXPRession
:MEASure:FUNCtion<x>[:STATe]
:MEASure:FUNCtion<x>:UNIT
:MEASure:MHOLd
:MEASure:PC?
:MEASure:PC:IEC
:MEASure:PC:P<x>
:MEASure:PHASe
:MEASure:SFORmula
NUMeric Group
:NUMeric?
:NUMeric:FORMat
:NUMeric:IMPedance?
:NUMeric:IMPedance:ARRay
:NUMeric:IMPedance:CLEar
:NUMeric:IMPedance:ITEM<x>
:NUMeric:IMPedance:NUMber
:NUMeric:IMPedance:PRESet
:NUMeric:IMPedance:VALue?
:NUMeric:NORMal?
:NUMeric[:NORMal]:CLEar
:NUMeric[:NORMal]:ITEM<x>
:NUMeric[:NORMal]:NUMber
:NUMeric[:NORMal]:PRESet
:NUMeric[:NORMal]:VALue?
RATE Group
:RATE
STATus Group
:STATus?
:STATus:CONDition?
:STATus:EESE
:STATus:EESR?
:STATus:ERRor?
:STATus:FILTer<x>
:STATus:QENable
5-8
Function
Queries all settings related to user-defined functions.
Sets the equation of the user-defined function or queries the current setting. 5-63
Enables (ON) or Disables (OFF) the user-defined function or queries
the current setting.
Sets the unit to be added to the computation result of the user-defined
function or queries the current setting.
Turns ON/OFF the MAX HOLD function or queries the current setting.
Queries all settings related to the calculation of Pc (Corrected Power).
Sets the equation used to calculate Pc (Corrected Power) or queries
the current setting.
Sets the parameter used to calculate Pc (Corrected Power) or queries
the current setting.
Sets the display format of the phase difference or queries the
current setting.
Sets the equation used to calculate S (reactive power) or queries the
current setting.
Queries all settings related to the numeric data output.
Sets the format of the numeric data that is transmitted by
":NUMeric:{NORMal|HARMonics|LIST:VALue?" or queries the current setting.
Queries all settings related to the numeric data output for impedance
measurement.
Sets the number of data points (the number of arrays) when outputting
an array-type function or queries the current setting.
Clears the numeric data output items for impedance measurement.
Sets the numeric data output items for impedance measurement or
queries the current setting.
Sets the number of items of the numeric data that is transmitted by
":NUMeric:IMPedance:VALue?" or queries the current setting.
Presets the pattern of the numeric data output items for impedance
measurement.
Queries the numeric data for impedance measurement.
Queries all settings related to the numeric data output for power
measurement.
Clears the numeric data output item for power measurement.
Sets the numeric data output items for power measurement or
queries the current setting.
Sets the number of the numeric data that is transmitted by
":NUMeric:NORMal:VALue?" or queries the current setting.
Presets the output item pattern of numeric data for power measurement.
Queries the numeric data for power measurement.
Sets the data update rate for power measurement or queries the current setting.
Queries all settings related to the communication status function.
Queries the contents of the condition register.
Sets the extended event enable register or queries the current setting.
Queries the content of the extended event register and clears the register.
Queries the error code and message information (top of the error queue).
Sets the transition filter or queries the current setting.
Sets whether or not to store messages other than errors to the error
queue (ON/OFF) or queries the current setting.
Page
5-63
5-63
5-63
5-63
5-64
5-64
5-64
5-64
5-64
5-66
5-66
5-66
5-66
5-66
5-67
5-67
5-67
5-67
5-67
5-68
5-68
5-68
5-68
5-68
5-71
5-72
5-72
5-72
5-72
5-73
5-73
5-73
IM 760151-17E

Advertisement

Table of Contents
loading

Table of Contents