5.4 DISPlay Group
:DISPlay:TRENd:NORMal?
Function
Queries all settings related to all the trends for
power measurement.
Syntax
:DISPlay:TRENd:NORMal?
Example
:DISPLAY:TREND:NORMAL? ->
:DISPLAY:TREND:NORMAL:ITEM1:
FUNCTION URMS,1;SCALING:MODE AUTO;
VALUE 100.00E+00,-100.00E+00;:
DISPLAY:TREND:NORMAL:ITEM2:
FUNCTION IRMS,1;SCALING:MODE AUTO;
VALUE 100.00E+00,-100.00E+00;...
(omitted)...;:DISPLAY:TREND:NORMAL:
ITEM16:FUNCTION FU,2;SCALING:
MODE AUTO;VALUE 100.00E+00,
-100.00E+00
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
:DISPlay:TRENd:NORMal:ITEM<x>?
Function
Queries all settings related to the trend for
power measurement.
Syntax
:DISPlay:TRENd:NORMal:ITEM<x>?
<x> = 1 to 16 (item number)
Example
:DISPLAY:TREND:NORMAL:ITEM1? ->
:DISPLAY:TREND:NORMAL:ITEM1:
FUNCTION URMS,1;SCALING:MODE AUTO;
VALUE 100.00E+00,-100.00E+00
Description This command is invalid on models that are only
equipped with impedance measurement elements,
since the mode is fixed to impedance measurement.
:DISPlay:TRENd:NORMal:ITEM<x>[:FUNCtion]
Function
Sets the trend item for power measurement or
queries the current setting.
Syntax
:DISPlay:TRENd:NORMal:ITEM<x>
[:FUNCtion] {NONE|<Function>,
<Element>}
:DISPlay:TRENd:NORMal:ITEM<x>:
FUNCtion?
<x> = 1 to 16 (item number)
NONE = No display item
<Function> = {URMS|UMN|UDC|UAC|IRMS|
...} (See the function selection
list (1).")
<Element> =
{<NRf>|SIGMA|SIGMB|SIGMC}(<NRf> = 1 to
4) (power measurement element)
Example
:DISPLAY:TREND:NORMAL:ITEM1:
FUNCTION URMS,1
:DISPLAY:TREND:NORMAL:ITEM1:
FUNCTION? -> :DISPLAY:TREND:NORMAL:
ITEM1:FUNCTION URMS,1
5-24
Description This command is invalid on models that are only
equipped with impedance measurement elements,
since the mode is fixed to impedance measurement.
:DISPlay:TRENd:NORMal:ITEM<x>:SCALing?
Function
Queries all settings related to the scaling of the
trend for power measurement.
Syntax
:DISPlay:TRENd:NORMal:ITEM<x>:
SCALing?
<x> = 1 to 16 (item number)
Example
:DISPLAY:TREND:NORMAL:ITEM1:
SCALING? -> :DISPLAY:TREND:NORMAL:
ITEM1:SCALING:MODE AUTO;
VALUE 100.00E+00,-100.00E+00
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
:DISPlay:TRENd:NORMal:ITEM<x>:SCALing:
MODE
Function
Sets the scaling mode of the trend for power
measurement or queries the current setting.
Syntax
:DISPlay:TRENd:NORMal:ITEM<x>:
SCALing:MODE {AUTO|MANual}
:DISPlay:TRENd:NORMal:ITEM<x>:
SCALing:MODE?
<x> = 1 to 16 (item number)
Example
:DISPLAY:TREND:NORMAL:ITEM1:
SCALING:MODE AUTO
:DISPLAY:TREND:NORMAL:ITEM1:
SCALING:MODE? -> :DISPLAY:TREND:
NORMAL:ITEM1:SCALING:MODE AUTO
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
:DISPlay:TRENd:NORMal:ITEM<x>:SCALing:
VALue
Function
Sets the upper and lower limits of manual
scaling of the trend for power measurement or
queries the current setting.
Syntax
:DISPlay:TRENd:NORMal:ITEM<x>:
SCALing:VALue {<NRf>,<NRf>}
:DISPlay:TRENd:NORMal:ITEM<x>:
SCALing:VALue?
<x> = 1 to 16 (item number)
<NRf> = –9.9999E+30 to 9.9999E+30
Example
:DISPLAY:TREND:NORMAL:ITEM1:
SCALING:VALUE 100,-100
:DISPLAY:TREND:NORMAL:ITEM1:
SCALING:VALUE? ->
:DISPLAY:TREND:NORMAL:ITEM1:
SCALING:VALUE 100.00E+00,
-100.00E+00