YOKOGAWA WT1600FC User Manual page 38

Impedance meter communication interface
Table of Contents

Advertisement

5.1 Command List
Command
:DISPlay[:NUMeric]:NORMal:IAMount
:DISPlay[:NUMeric]:NORMal:ICURsor
:DISPlay[:NUMeric]:NORMal:ITEM<x>
:DISPlay[:NUMeric]:NORMal:PRESet
:DISPlay:TRENd?
:DISPlay:TRENd:ALL
:DISPlay:TRENd:FORMat
:DISPlay:TRENd:NORMal?
:DISPlay:TRENd:NORMal:ITEM<x>?
:DISPlay:TRENd:NORMal:ITEM<x>[:FUNCtion]
:DISPlay:TRENd:NORMal:ITEM<x>:SCALing?
:DISPlay:TRENd:NORMal:ITEM<x>:SCALing:MODE
:DISPlay:TRENd:NORMal:ITEM<x>:SCALing:VALue
:DISPlay:TRENd:PDIV
:DISPlay:TRENd:RESTart
:DISPlay:TRENd[:SAMPling]
:DISPlay:TRENd:TDIV
:DISPlay:TRENd:T<x>
:DISPlay:WAVE?
:DISPlay:WAVE:ALL
:DISPlay:WAVE:FORMat
:DISPlay:WAVE:GRATicule
:DISPlay:WAVE:INTerpolate
:DISPlay:WAVE:MAPPing?
:DISPlay:WAVE:MAPPing[:MODE]
:DISPlay:WAVE:MAPPing:{U<x>|I<x>}
:DISPlay:WAVE:SVALue
:DISPlay:WAVE:TLABel
:DISPlay:WAVE:{U<x>|I<x>}
FILE Group
:FILE?
:FILE:CDIRectory
:FILE:DELete:IMAGe:{TIFF|BMP|PSCRipt}
:FILE:DELete:NUMeric:{ASCii|FLOat}
:FILE:DELete:SETup
:FILE:DELete:WAVE:{BINary|ASCii|FLOat}
:FILE:DRIVe
5-2
Function
Sets the numeric display format for power measurement or queries the
current setting.
Sets the cursor position on the numeric display (split display) for power
measurement or queries the current setting.
Sets the numeric display item for power measurement or queries the
current setting.
Presets the display order pattern of numeric display items for power measurement. 5-23
Queries all settings related to the trend.
Collectively turns ON/OFF all trends.
Sets the display format of the trend or queries the current setting.
Queries all settings related to all the trends for power measurement.
Queries all settings related to the trend for power measurement.
Sets the trend item for power measurement or queries the current setting.
Queries all settings related to the scaling of the trend for power measurement.
Sets the scaling of the trend for power measurement or queries the current setting. 5-24
Sets the upper and lower limits of manual scaling of the trend for power
measurement or queries the current setting.
Sets the horizontal axis (Point/div) of the trend or queries the current setting. 5-25
Restarts the trend.
Turns ON/OFF the trend waveform sampling or queries the current setting.
Sets the horizontal axis (T/div) of the trend for power measurement or
queries the current setting.
Turns ON/OFF the trend or queries the current setting.
Queries all settings related to the waveform display.
Collectively turns ON/OFF all waveform displays.
Sets the display format of the waveform or queries the current setting.
Sets the graticule (grid) type or queries the current setting.
Sets the interpolation method of the waveform or queries the current setting. 5-26
Queries all settings related to the waveform mapping to the split screen.
Sets the waveform mapping method for the split screen or queries
the current setting.
Sets the waveform mapping to the split screen or queries the current setting. 5-26
Turns ON/OFF the scale value display or queries the current setting.
Turns ON/OFF the waveform labels or queries the current setting.
Turns ON/OFF the waveform display or queries the current setting.
Queries all settings related to the file operation.
Changes the current directory.
Deletes the screen image data file.
Deletes the numeric data file.
Deletes the setup parameter file.
Deletes the waveform display data file.
Sets the target drive.
Page
5-22
5-22
5-23
5-23
5-23
5-23
5-24
5-24
5-24
5-24
5-24
5-25
5-25
5-25
5-25
5-25
5-26
5-26
5-26
5-26
5-26
5-27
5-27
5-27
5-26
5-26
5-26
5-26
5-29
5-29
5-29
IM 760151-17E