5.10 INPut Group
[:INPut]:CURRent:RANGe:ELEMent<x>
Function
Sets the current range of the power
measurement element or queries the current
setting.
Syntax
[:INPut]:CURRent:RANGe:
ELEMent<x>
{<Current>|<Voltage>|AUTO}
[:INPut]:CURRent:RANGe:ELEMent<x>?
<x> = 1 to 4 (power measurement element)
• For a 5-A input element
<Current > = 10, 20, 50, 100, 200, 500 (mA),
1, 2, or 5 (A) (when TERMinal = DIRect)
<Voltage > = 50, 100, 250, 500 (mV), 1, 2.5,
5, or 10 (V)
AUTO = Auto range
• For a 50-A input element
<Current> = 1, 2, 5, 10, 20, or 50 (A)
(when TERMinal = DIRect)
<Voltage> = 50, 100, 250, 500 (mV), 1, 2.5,
5, or 10 (V)
AUTO = Auto range
Example
:INPUT:CURRENT:RANGE:ELEMENT1 5A
:INPUT:CURRENT:RANGE:ELEMENT1? ->
:INPUT:CURRENT:RANGE:
ELEMENT1 5.00E+00
Description • The selectable range is determined by the
input element type (5A/50A) of the target
element and the current measurement
terminal setting ([:INPut]:
CURRent:TERMinal:ELEMent<x>).
• Specifying "Auto" with this command is
equivalent to setting
"[:INPut]:CURRent:AUTO:
ELEMent<x>" to "ON."
• This command is invalid on models that are
only equipped with impedance measurement
elements, since the mode is fixed to
impedance measurement.
[:INPut]:CURRent:SRATio?
Function
Queries the current sensor scaling constants of
all power measurement elements.
Syntax
[:INPut]:CURRent:SRATio?
Example
:INPUT:CURRENT:SRATIO? -> :INPUT:
CURRENT:SRATIO:ELEMENT1 10.0000;
ELEMENT2 10.0000;ELEMENT3 10.0000;
ELEMENT4 10.0000
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
5-50
(when TERMinal = SENSor)
(when TERMinal = SENSor)
[:INPut]:CURRent:SRATio[:ALL]
Function
Collectively sets the current sensor scaling
constants of all power measurement elements.
Syntax
[:INPut]:CURRent:SRATio
[:ALL] {<NRf>}
<NRf> = 0.0001 to 99999.9999
Example
:INPUT:CURRENT:SRATIO:ALL 10
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
[:INPut]:CURRent:SRATio:ELEMent<x>
Function
Sets the current sensor scaling constant of the
power measurement element or queries the
current setting.
Syntax
[:INPut]:CURRent:SRATio:
ELEMent<x> {<NRf>}
[:INPut]:CURRent:SRATio:ELEMent<x>?
<x> = 1 to 4 (power measurement element)
<NRf> = 0.0001 to 99999.9999
Example
:INPUT:CURRENT:SRATIO:ELEMENT1 10
:INPUT:CURRENT:SRATIO:ELEMENT1? ->
:INPUT:CURRENT:SRATIO:
ELEMENT1 10.0000
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
[:INPut]:CURRent:TERMinal?
Function
Queries the current measurement terminal of all
power measurement elements.
Syntax
[:INPut]:CURRent:TERMinal?
Example
:INPUT:CURRENT:TERMINAL? -> :INPUT:
CURRENT:TERMINAL:ELEMENT1 DIRECT;
ELEMENT2 DIRECT;ELEMENT3 DIRECT;
ELEMENT4 DIRECT
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.
[:INPut]:CURRent:TERMinal[:ALL]
Function
Collectively sets the current measurement
terminals of all power measurement elements.
Syntax
[:INPut]:CURRent:TERMinal
[:ALL] {DIRect|SENSor}
DIRect = Direct input
SENSor = Current sensor input
Example
:INPUT:CURRENT:TERMINAL:ALL DIRECT
Description This command is invalid on models that are only
equipped with impedance measurement
elements, since the mode is fixed to impedance
measurement.