Caution
Before welding commences, make sure that the room is properly ventilated. Always
wear the personal protective equipment. Observe and obey the relevant safety
instructions.
Earth strap
A
Bolt the shock absorber to the bulkhead.
B
Secure the shock absorber assembly to the top of the cabinet.
C
Cable entry is found at the top and/or bottom of the cabinet.
Note
Ensure maximum physical distance between the Wide Band Transceiver (WBT) and the
Power Supply Unit. This is important to reduce noise. Place the power supplies on a
dedicated drawer at the bottom of the cabinet.
How to install the cables in the WBT Cabinet is described on drawing 444425. The
drawing can be downloaded from our website. The drawing is also included on the
EK80 USB.
Procedure
1
Prepare the installation of the cabinet.
a
Observe the outline dimensions drawing.
The drawing is located in the Drawing file chapter in this manual. It can also
be downloaded from our website.
https://www.kongsberg.com/simrad
394149/D
Installing the EK80 hardware units
79