Kongsberg Simrad EK80 Installation Manual page 110

Hide thumbs Also See for Simrad EK80:
Table of Contents

Advertisement

Simrad EK80 Installation Manual
A
The junction box is isolated
from vessel ground.
Cable gland
B
Terminal block
C
D
Cable
Cable screen (Do not connect
E
the cable screen to vessel
ground.)
Procedure
1
Mount the junction box in a
suitable location.
2
Terminate the steel conduits
containing the transducer cable
as close to the junction box as
possible.
3
Make sure that the junction
box chassis is not connected
to vessel ground.
Use additional insulation if this is necessary to isolate the junction box completely.
4
Remove the insulation from the transducer cable. Connect the individual wires
to the terminal block.
5
Remove the insulation from the extension cable. Connect the individual wires
to the terminal block.
6
Make sure that you have connected the wires 1:1, and that the colours match.
7
Connect the cable screens to the cable glands in the junction box.
Related topics
Splicing the transducer cable, page 107
Cable layout and interconnections, page 85
Splicing the cable using a grounded junction box
Do not solder the wires together using only electrical tape for insulation. This will result
in electrical noise and reduced operational performance.
108
394149/D

Advertisement

Table of Contents
loading

Table of Contents