Kongsberg Simrad EK80 Installation Manual page 132

Hide thumbs Also See for Simrad EK80:
Table of Contents

Advertisement

Simrad EK80 Installation Manual
The synchronization output on the Auxiliary socket offers a "high" pulse (5 V, 100Ω)
that stays "high" during the entire "ping" cyclus. The pulse is always there no matter
which synchronization settings you make in the user interface. The output can be used to
synchronize other hydrographic systems with the EK80 as "master".
The socket fits a Conxall 7-pin Mini-Con-X
shielded plug. The connections are made on
pins 2, 3 and 5. The plug can be ordered from
the manufacturer or purchased from Kongsberg
Maritime. Use part number 387563.
: Switchcraft Conxall
Manufacturer
Manufacturer's website
Pin number
Signal
Pin number
Signal
Digital ground
The parameters on the
port to use for the physical connection to the external system, and which synchronization
mode to use. The
Synchronization
menu.
Setup
Note
If you use more than one Wide Band Transceiver (WBT) in your EK80 system, all
synchronization input signals to the
source. Individual synchronization of a single Wide Band Transceiver (WBT) is not
supported.
If you use more than one computer in your EK80 system, the synchronization inputs to
Auxiliary
the
ports can not be used. This functionality is not supported.
Related topics
Setting up the EK80 in a synchronized system, page 126
Cable layout and interconnections, page 85
130
:
http://www.conxall.com
1
Future use
Synchronization
Output
5
Not used
page allow you to choose which communication
Synchronization
page is located in the
Auxiliary
®
2
3
Synchronization
Input
6
7
Not used
Installation
ports must be provided by the same
4
Future use
dialog box on the
394149/D