Kongsberg EK80 Quick Start Manual
Hide thumbs Also See for EK80:

Advertisement

Quick Links

PUBLIC
Doc ID:
401925
Revision:
D
Project:
Product:
Status:
This document is under configuration control at Kongsberg Maritime.
KONGSBERG PROPRIETARY. This document and its accompanying elements contain KONGSBERG information which is proprietary and confidential. Any
disclosure, copying, distribution or use is prohibited if not otherwise explicitly agreed with KONGSBERG in writing. Any authorized reproduction, in
whole or in part, must include this legend. ©2021 KONGSBERG - All rights reserved.
EK80 HAT procedure

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EK80 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kongsberg EK80

  • Page 1 KONGSBERG PROPRIETARY. This document and its accompanying elements contain KONGSBERG information which is proprietary and confidential. Any disclosure, copying, distribution or use is prohibited if not otherwise explicitly agreed with KONGSBERG in writing. Any authorized reproduction, in whole or in part, must include this legend. ©2021 KONGSBERG - All rights reserved.
  • Page 2 Disclaimer Kongsberg Maritime AS endeavours to ensure that all information in this document is correct and fairly stated, but does not accept liability for any errors or omissions unless and to the extent otherwise is expressly agreed in writing between the parties under contract.
  • Page 3: Table Of Contents

    Noise measurements ................... 8 2.3.7 Data download ..................... 9 List of Items........................10 Check List ........................12 Customer Acceptance Form ..................15 KONGSBERG PROPRIETARY – see Statement of Proprietary Information 401925 / D / 2021-08-17 / Page 3 of 15...
  • Page 4: Introduction

    1 INTRODUCTION The purpose of this Harbour Acceptance Test (HAT) is to verify that the Echosounders and/or the ADCPs in the EK80 system are correctly installed, and fully functional. It is then ready for the Sea Acceptance Test (SAT). After the HAT, the Customer Acceptance Form must be signed by the relevant parties. The completed document then becomes the official report.
  • Page 5: Hat Procedure Ek80

    Kongsberg Maritime AS PUBLIC 2 HAT PROCEDURE EK80 2.1 Hardware and Software registration In Table 3 List of Items, fill in the information for all the units supplied by Kongsberg Maritime. The items supplied can be: • Computer • Network switch •...
  • Page 6: Dimensional Survey

    2.3.3 Dimensional survey A dimensional survey must be present for the HAT to be approved. Note! The accuracy requirements for the dimensional survey are listed in the EK80 installation manual and the EC150-3C installation manual. Note! Modest accuracy requirements apply when your EK80 system is only used to investigate objects in the water column.
  • Page 7: Functional Test Of Adcp

    Verify that you see the bottom return in the echogram and that all beams detect the bottom. Check if you measure any velocities in the water column. KONGSBERG PROPRIETARY – see Statement of Proprietary Information 401925 / D / 2021-08-17 / Page 7 of 15...
  • Page 8: Noise Measurements

    Disconnect the transducer cables from all the WBTs and connect the shielded dummy load (P/N 453635). Activate the system(s) with the dummy load connected and log data for 5 minutes. KONGSBERG PROPRIETARY – see Statement of Proprietary Information 401925 / D / 2021-08-17 / Page 8 of 15...
  • Page 9: Data Download

    KM local server. The data will be used for future reference. Alternatively, the technical report must include screenshots of installation menus and echograms for documentation. KONGSBERG PROPRIETARY – see Statement of Proprietary Information 401925 / D / 2021-08-17 / Page 9 of 15...
  • Page 10: List Of Items

    Serial no.: Transducer #3 Model: Serial no.: Transducer #4 Model: Serial no.: Transducer #5 Model: Serial no.: Transducer #6 Model: Serial no.: KONGSBERG PROPRIETARY – see Statement of Proprietary Information 401925 / D / 2021-08-17 / Page 10 of 15...
  • Page 11 Kongsberg Maritime AS PUBLIC ADCP Model: FW version: Serial no.: KONGSBERG PROPRIETARY – see Statement of Proprietary Information 401925 / D / 2021-08-17 / Page 11 of 15...
  • Page 12: Check List

    2.3.3 Dimensional survey Functional test of Echosounders 2.3.4.1 Normal operation Transducer measurements 2.3.4.2.1 CW pulses 18 kHz 60Ω < Z < 95Ω KONGSBERG PROPRIETARY – see Statement of Proprietary Information 401925 / D / 2021-08-17 / Page 12 of 15...
  • Page 13 333 kHz 2.3.5 Functional test of ADCP 2.3.6 Noise measurements 2.3.6.2.1 Noise data with transducer 18 kHz Noise estimate 38 kHz Noise estimate KONGSBERG PROPRIETARY – see Statement of Proprietary Information 401925 / D / 2021-08-17 / Page 13 of 15...
  • Page 14 38 kHz Noise estimate 70 kHz Noise estimate 120 kHz Noise estimate 200 kHz Noise estimate 333 kHz Noise estimate 2.3.7 Data download KONGSBERG PROPRIETARY – see Statement of Proprietary Information 401925 / D / 2021-08-17 / Page 14 of 15...
  • Page 15: Customer Acceptance Form

    Kongsberg Maritime AS PUBLIC 5 CUSTOMER ACCEPTANCE FORM The HARBOR ACCEPTANCE TEST for the EK80, for …………………………...…. has been performed according to the test procedure. The test is: Accepted / Not accepted (Delete as appropriate) Remarks: Please use capital letters:...

Table of Contents