You must be equipped with a standard set of tools. This tool set must comprise the
normal tools for cable installation tasks. This includes different screwdriver types,
pliers, spanners, a cable stripper, a soldering iron, etc. Each tool must be provided in
various sizes. We recommend that all tools are demagnetized to protect your equipment.
Depending on the tasks at hand, additional tools may be required.
Context
The Auxiliary socket on the Wide Band
Transceiver (WBT) can be used to interface an
external synchronization system.
The socket fits a Conxall 7-pin Mini-Con-X
shielded plug. The connections are made on pins
2, 3 and 5. The plug can be ordered from the
manufacturer or purchased from Kongsberg Maritime. Use part number 387563.
: Switchcraft Conxall
Manufacturer
Manufacturer's website
Pin number
Signal
Pin number
Signal
Digital ground
The parameters on the
port to use for the physical connection to the external system, and which synchronization
mode to use. The
Synchronization
menu.
Setup
Note
If you use more than one Wide Band Transceiver (WBT) in your EK80 system, all
synchronization input signals to the
source. Individual synchronization of a single Wide Band Transceiver (WBT) is not
supported.
If you use more than one computer in your EK80 system, the synchronization inputs to
Auxiliary
the
ports can not be used. This functionality is not supported.
The
Synchronization Delay
your Wide Band Transceiver (WBT) to synchronize the EK80.
Procedure
1
Connect the dedicated cable from the Wide Band Transceiver (WBT) to the external
synchronisation system.
This is described in the Cable layout and interconnections chapter. Observe the
applicable requirements related to cabling.
394149/D
:
http://www.conxall.com
1
Future use
Synchronization
Output
5
Not used
page allow you to choose which communication
Synchronization
page is located in the
Auxiliary
functionality is unavailable if you use the
®
2
3
Synchronization
Input
6
7
Not used
Installation
ports must be provided by the same
Setting to work
4
Future use
dialog box on the
Auxiliary
port on