Open the operating systems's Network and Sharing Center, and set the IP
d
address for the network adapter used to communicate with the transceiver.
IP Address
Any address can be used, but 157.237.15.12 is recommended for legacy
reasons. This is particularly important if your system contains old GPT
transceivers.
Subnet mask
You can leave
message saying that the message subnet mask is missing, select
A default subnet mask is then automatically generated.
2
Install the EK80 operational software.
3
Turn on the transceiver(s).
4
Make sure that the Processor Unit is connected to the transceiver(s) using the
Ethernet cable specified in the EK80 Installation manual.
If you use more than one transceiver, a high performance Ethernet switch must
be used.
Note
It is very important that high-quality Ethernet cables are used. You must use
CAT-5E STP (Shielded Twisted Pair) quality or better. If you use cables with lower
bandwidth capacity you will reduce the EK80 performance.
5
Start the EK80.
6
On the
Software License
7
On the
Transducer
8
On the
Transceiver Installation
9
On the
Sensor Installation
10 In the
Environment
11 Start normal operation.
a
On the
File Setup
b
Set
Operation
c
In the
Normal Operation
d
Set
Ping Mode
e
With the
Ping Interval
for the survey.
f
Set
to On.
Ping
200
: 157.237.15.12
: 255.255.255.0
blank and select
Subnet mask
page, install the software license(s).
page, install each transducer.
page, connect the transducer(s) to the transceiver(s).
page, set up the interfaces to the navigation sensors.
dialog box, select correct water temperature and salinity.
page, define the recording parameters.
to Normal.
dialog box, set the operating parameters.
to Interval.
function, specify the ping rate that has been defined
. When you see an error
OK
OK
again.
394149/D