Sign In
Upload
Manuals
Brands
Kongsberg Manuals
Marine Equipment
Simrad EK80
Kongsberg Simrad EK80 Manuals
Manuals and User Guides for Kongsberg Simrad EK80. We have
6
Kongsberg Simrad EK80 manuals available for free PDF download: Reference Manual, Installation Manual, Instruction Manual, Quick Start Manual
Kongsberg Simrad EK80 Reference Manual (894 pages)
Wide band scientific echo sounder
Brand:
Kongsberg
| Category:
Marine Equipment
| Size: 39.33 MB
Table of Contents
Table of Contents
4
About this Manual
18
Ek80
21
Important
21
System Description
22
System Diagram
24
Main System Units
27
Display Description
27
Processing Unit Description
28
Ethernet Switch Description
29
Transceiver Unit Description
29
Transducer Description
32
Kongsberg EC150-3C
32
Network Security
34
Support Information
35
Getting Started
36
Starting Normal Operation
37
Turning on the EK80 System
37
Getting to Know the User Interface
38
Checking Transceiver and Transducer Settings
40
Selecting Normal Mode to Start Pinging
42
Switching between ADCP and Echo Sounder Operation
43
Verifying that the Bottom Is Correctly Detected
44
Checking And/Or Editing the Transceiver Parameters
45
Turning off the EK80 System
46
Basic Operation
48
Selecting Which Echogram Type to Use
48
Selecting Which Velocity Measurement (ADCP) Views to Present
50
Adjusting the Minimum Level (Echo Sensitivity)
52
Choosing the Depth Range and the Start Depth for the Echograms
53
Choosing the Colours Used to Present the Echograms
55
Opening the Context-Sensitive Online Help
56
Defining the File and Folder Settings for Raw Data Recording
57
Defining the File and Folder Settings for Processed Data Recording
59
Recording Raw Data
61
Recording Processed Data
62
Target Strength Calibration Summary
64
User Interface Introduction
68
User Interface Familiarization
69
Echogram Views
70
Velocity Measurement (ADCP) Views
73
Top Bar Description
74
Information Pane
75
Menu System
79
Working with Depth Layers
80
Setting up the EK80 Wide Band Scientific Echo Sounder for the First Time
83
Setting up Summary
83
Installing the EK80 Operating Software
85
Turning on the EK80 System for Passive Mode
86
Obtaining and Installing the Software License
87
Defining the IP Address on the Processing Unit Network Adapter for Communication with the Transceiver
89
Installing One or more Transducers
91
Installing Transceiver Channels
94
Adjusting the Screen Resolution
97
Setting up the EC150-3C for ADCP in EK80
99
Defining the IP Address on the Processing Unit Network Adapter for Communication with the EC150-3C
99
Installing an ADCP Transceiver as a Transceiver Channel
101
Defining the EC150-3C Installation Parameters
103
Obtaining and Installing the Software License for EC150-3C
105
Assembling a Portable EK80 System
107
System Diagram, Portable
107
Assembling a Portable System
108
Battery Power Cable (WBT)
109
GPT Transducer Plug Connections
110
12-Pin Amphenol Plug
110
Operating Procedures
112
Choosing Operating Mode and Key Transmit Parameters
114
Selecting Normal Mode
114
Selecting Inactive Mode
115
Selecting Replay Mode
116
Selecting Advanced Sequencing Mode
117
Verifying that the Bottom Is Correctly Detected
118
Defining the Ping (Transmission) Modes
120
Transmitting Single Pings
121
Transmitting with Fixed-Time Intervals
122
Switching between ADCP and Echo Sounder Operation
123
Opening the Context-Sensitive Online Help
124
Controlling the Gain and Range Settings
125
Adjusting the Minimum Level (Echo Sensitivity)
125
Adjusting the TVG (Time Variable Gain) Setting
126
Choosing Range and Start Range Values in a Surface-Related Echogram
127
Choosing Range and Start Range Values in a Bottom-Related Echogram
129
Defining the Environmental Settings
131
Configuring the Environmental Parameters
131
Defining the Sound Speed Close to the Transducer
132
Loading a Sound Speed Profile
133
Setting up the Input from a Sound Speed Sensor
133
Recording and Replaying Raw Echo Data
136
Defining the Raw Data Recording Parameters
136
Recording Raw Data
138
Selecting Replay Mode
140
Choosing Which Raw Data File(S) to Replay
141
Locating the Raw Data Files to Delete, Move or Copy Them
142
Defining the Depth Range for Raw Data Recording
143
Reducing the Raw Data File Sizes During CW Recording
144
Disabling the Automatic Echogram History Recording
145
Recording and Exporting Processed Echo Data
147
Defining the Processed Data Recording Parameters
147
Defining Recording Formats for ADCP Netcdf Outputs
149
Recording Processed Data
151
Locating the Processed Data Files to Delete, Move or Copy Them
153
Setting up Depth Output to an External System
154
Exporting Sensor Data to a Peripheral System
156
Saving and Recalling Screen Captures
158
Saving a Screen Capture
158
Recalling Single Echogram Screen Capture Images
159
Accessing the Screen Capture Images to Delete, Move or Copy Them
160
Capturing the Display Presentation in Video Files
162
Capturing the Display Presentation in a Video File
162
Selecting Where to Save the Video Files
163
Setting up the Echogram Presentation
164
Selecting Which Echogram Type to Use
164
Selecting Echogram Views on the Bottom Bar
166
Changing the Size of the Echogram Views
167
Defining the Ping (Transmission) Modes
168
Choosing the Colours Used to Present the Echograms
169
Adjusting the TVG in the Echogram Dialog Box
171
Selecting the Horizontal Scale in the Echograms
172
Adding Scale Labels to the Echograms
174
Adding Horizontal Depth Lines to the Echograms
175
Monitoring the Biomass in the Echogram
176
Enhancing the Bottom Contour in the Echograms
177
Adding Vertical Marker Lines to the Echogram
178
Adding Automatic Trawl Lines to the Echogram Presentation
179
Adding Manual Trawl Lines to the Echogram Presentation
180
Adding Comments and Annotations to the Echograms
181
Adding a Single Text Comment to the Echogram
183
Monitoring the Survey Operations from a Client Computer
184
Using the Information Panes to Collect Data from the Echoes
186
Increasing the Visibility of the Information Panes
186
Retrieving the Latest Echogram History
187
Disabling the Automatic Echogram History Recording
188
Changing the Colour Scale in the Echo Presentations
189
Opening the Depth Information Pane to Read the Current Depth
191
Investigating the Bottom Characteristics
192
Changing the Calculation Parameters for the TS Histogram Information Pane
193
Investigating the Biomass
194
Changing the Calculation Parameters for the Biomass Information Pane
195
Creating a Sv(F) Information Pane with Echo Data from Multiple Channels
196
Monitoring the Numerical Information in a Depth Layer
198
Using the Zoom Information Pane to Study Details in the Echogram
200
Monitoring the Supply Voltage
201
Working with Depth Layers in the Echogram Views
203
Creating a New Depth Layer
203
Modifying the Properties of an Existing Depth Layer
206
Deleting a Depth Layer
207
Monitoring the Numerical Information in a Depth Layer
209
Exploring Water Velocities Using ADCP
211
Opening the ADCP (Acoustic Doppler Current Profiler) Information Pane
211
Identifying the Vessel Heading in the ADCP Information Pane
213
Selecting Compass Orientation for Horizontal Water Velocities
214
Controlling the Scale in the Compass Rose Presentation
215
Setting the Velocity Vectors to True or Relative Bearing
216
Setting the Compass Rose Presentation to True or Relative Bearing
218
Providing Vertical Velocity in the ADCP Information Pane
219
Changing the Speed Range Display for Vertical Current Velocity
220
Adjusting the ADCP Quality Parameters
222
Enabling ADCP Quality Parameters
222
Improving ADCP Data Quality Using an Error Velocity Threshold Limit
224
Improving ADCP Data Quality with a Correlation Threshold Value
225
Improving ADCP Data Quality with a Percent Good Threshold Value
226
Setting up the ADCP Presentation
228
Selecting Which Velocity Measurement (ADCP) Views to Present
228
Selecting Velocity Measurement (ADCP) Views Using the Bottom Bar
230
Changing the Size of the Individual Velocity Measurement (ADCP) Views
231
Placing Velocity Measurement (ADCP) Views in a Separate Window
232
Adjusting the Colours in the Velocity Measurement (ADCP) Views
234
Reducing the Random Errors in ADCP Measurements
235
Selecting the Horizontal Scale in the ADCP Views
236
Adding Scale Labels to the ADCP Views
237
Enhancing the Bottom Contour in ADCP Views
238
Setting the Drawing Range for the ADCP Views
239
Adding Vertical Marker Lines to the ADCP Views
241
Adding Comments and Annotations to ADCP Views
242
Adding a Single Text Comment to an ADCP View
243
Working with Advanced Sequences
244
Creating an Advanced Sequence
244
Editing an Advanced Sequence
246
Creating an Advanced Sequence - Example
247
Uploading and Activating an Advanced Sequence
249
Deactivating an Advanced Sequence
250
Working with Pings, Ping Groups and Ensembles
251
Defining a Ping
251
Creating a Ping Group
252
Creating Ensembles
254
Setting up Presentation Modes and Views
256
Placing Echogram Channels in Separate Windows on Multiple Displays
256
Rearranging the Layout of the Echo Presentations
257
Moving a View to Another Display
258
Restoring the Locations and Sizes of the Views
259
Rearranging the Tabs at the Bottom of the EK80 Presentation
260
Creating Personalized Views by Adding a New Tab to the Bottom of the EK80 Presentation
261
Removing Personalized Presentations
262
Defining Settings Related to User Preferences and Individual Customizing
263
Reducing the Light Emitted from the Display Presentation
263
Increasing the Visibility of the Information Panes
264
Enabling Coordinated Universal Time (UTC) on the Bottom Bar
265
Selecting the Information to Appear on the Top Bar
266
Selecting Which Tooltips to Appear in the User Interface
267
Changing the Colour Palette ("Skin") Used in the Display Presentations
267
Selecting Menu Language
268
Selecting Measurement Units
269
Saving, Retrieving and Handling User Settings
270
Saving the Current User Settings
270
Choosing Previously Saved User Settings
271
Renaming Existing User Settings
272
Deleting User Settings that Are no Longer Used
273
Choosing Factory Default Settings
274
Adjusting the Transceiver Parameters
275
Checking And/Or Editing the Transceiver Parameters
275
Selecting Passive Transceiver Mode
276
Adjusting the Output Power
277
Adjusting the Pulse Duration
278
Defining the Frequency Sweep (Chirp) Within each Transmission
279
Defining the Pulse Type for the EK80 Transmissions
280
Increasing the Detection of Small Targets Masked by Stronger Echoes
281
Switching between ADCP and Echo Sounder Operation
282
Adjusting the Specific Transceiver Parameters for ADCP Operation
283
Measuring the Noise in Passive Mode
284
Interfacing Peripheral Equipment
286
Installing Navigation Sensors and Other Sensors
286
Defining the Serial and Ethernet (LAN) Port Parameters
288
Setting up the Input from a Navigation System (GPS)
289
Configuring the Sensor Priority
292
Setting up a Serial or LAN (Ethernet) Port for Annotation Input
294
Connecting a Catch Monitoring System to a Serial or LAN (Ethernet) Port
296
Connecting a Trawl System to a Serial or LAN (Ethernet) Port
298
Setting up the Input from a Motion Sensor
300
Setting up the Input from a Sound Speed Sensor
302
Setting up Depth Output to an External System
304
Exporting Sensor Data to a Peripheral System
306
Synchronizing the EK80 by Means of a Serial Port
307
Synchronizing the EK80 System by Means of the Auxiliary Port
310
Setting up the Interface between the EK80 and the Kongsberg TD50
312
Installing Transducers and Transceiver Channels in the User Interface
314
Defining the IP Address on the Processing Unit Network Adapter for Communication with the Transceiver
314
Installing One or more Transducers
316
Installing Towed Body Transducers
319
Installing the Transducer on a Drop Keel
322
Installing Transceiver Channels
324
Installing Multiplexed Transceiver Channels
327
Disconnecting Transceiver Channels
329
Installing an ADCP Transceiver in the User Interface
331
Summary of Procedures
331
Obtaining and Installing the Software License for EC150-3C
333
Defining the IP Address on the Processing Unit Network Adapter for Communication with the EC150-3C
335
Installing an ADCP Transceiver as a Transceiver Channel
337
Defining the EC150-3C Installation Parameters
339
Switching between ADCP and Echo Sounder Operation
341
Adjusting the Specific Transceiver Parameters for ADCP Operation
342
Setting up the EK80 System for Synchronized Operation
344
About Synchronization
344
Synchronization Modes
345
Synchronization Using Clear to Send (CTS) and Request to Send (RTS) Signals
346
Synchronization Sequences
346
Synchronizing the EK80 by Means of a Serial Port
347
Synchronizing the EK80 System by Means of the Auxiliary Port
350
Selecting Synchronization Mode
352
Serial Port Synchronization Signalling
354
Auxiliary Port Synchronization Signalling
354
Selecting Synchronization Port
357
Installing and Maintaining Software
358
Installing the EK80 Operating Software
358
Obtaining and Installing the Software License
359
Defining the IP Address on the Processing Unit Network Adapter for Communication with the Transceiver
361
Upgrading the EK80 Operating Software
363
Moving the Software License from One Computer to Another
364
Removing the EK80 Operating Software
365
Checking the Current Software Version
367
Upgrading the Software on the Transceiver
367
Maintaining the EK80 System
370
Checking Transceiver and Transducer Settings
370
Monitoring the Supply Voltage
372
Updating the Online Help System
374
Adding Online Help in a New Language
375
Accessing and Retrieving Message Log Files
377
Checking the Transducer by Means of the Diagnostics Functionality
378
Inspecting and Cleaning the Transducer Face
380
Painting the Transducer Face
381
Rules for Transducer Handling
383
Installing and Troubleshooting Network Time Protocol (NTP)
385
Installing Network Time Protocol (NTP)
385
Installing Network Time Protocol (NTP) Monitor
390
Troubleshooting the Network Time Protocol (NTP) Service
395
Noise Measurements at Sea
396
Set up the EK80 for Noise Measurements
396
Measuring Noise in Passive Operating Mode
398
Making a Noise/Speed Curve to Determine Vessel Noise
400
Collecting and Checking Noise Data
402
Calibration Procedures
406
User Interface
407
User Interface Familiarization
408
Top Bar
410
Top Bar Overview
410
Logo and Product Name
411
Menu
412
Screen Recording
412
Screen Capture
413
Record Indicator Description
413
Event
414
Information Panes Overview
415
Navigational Information
417
Messages
424
Help Button Description
424
Operating System Functions
425
Information Panes
426
Recording Information Pane Description
426
History Information Pane Description
428
Colour Scale Information Pane Description
430
Depth Information Pane Description
432
Bottom Hardness Information Pane Description
434
TS Histogram Information Pane Description
435
Target Position Information Pane
437
Ts(F) Information Pane Description
439
Biomass Information Pane Description
442
Sv(F) Information Pane Description
444
Numerical Information Pane Description
446
Zoom Information Pane Description
455
Transceiver Power Supply Information Pane Description
458
ADCP Information Pane
459
External Sensors Information Pane
464
Echogram Views
466
About the Echogram Views
466
Surface Echogram Description
468
Bottom Echogram Description
470
Pelagic Echogram Description
473
Trawl Echogram Description
475
Velocity Measurement (ADCP) Views
479
About the Velocity Measurement (ADCP) Views
479
Beam Velocity Views
481
Vessel Velocity Views
483
Geo Velocity Views
485
Backscatter Views
487
Correlation Views
489
Error Velocity View
491
Percent Good View
493
Lines and Markers
495
Annotation Markers Description
495
Bottom Line Description
496
Labels Description
497
Scale Lines Description
498
Trawl Line Description
499
Vertical Tick Description
500
White Line Description
501
Biomass Line Description
502
The EK80 Menu System
504
Bottom Bar Description
506
Replay Bar Description
507
Working with Depth Layers
508
Screen Capture Browser Description
511
Context-Sensitive Online Help
512
Menu System
513
About the Menus and Menu Buttons
514
Using the "Smart" Menu Buttons
515
Main Menu
517
Operation Menu
518
Display Menu
521
Setup Menu
523
Active Menu
529
Extras Menu
535
Functions and Dialog Boxes
540
Main Menu: Functions and Dialog Boxes
541
User Settings Dialog Box
541
Range Function
544
Start Range Function
545
Minimum Level Function
547
Operation Menu: Functions and Dialog Boxes
550
Operation Function
550
Normal Operation Dialog Box
553
Select Sequence Function
560
Ping Function
561
Ping Mode Function
562
Ping Interval Function
563
Record RAW Function
564
Record Processed Function
567
Output Dialog Box
570
Display Menu: Functions and Dialog Boxes
571
Screen Brightness Function
571
Transparency Function
572
Display Options Dialog Box
573
Colour Setup Dialog Box
573
Docking Views Function
575
Setup Menu: Functions and Dialog Boxes
578
Environment Dialog Box
578
Manual Annotation Dialog Box
579
Calibration Function
580
Calculation Interval Dialog Box
582
Advanced Sequencing Dialog Box
584
Installation Dialog Box
586
Language Function
587
Diagnostics Dialog Box
588
About Dialog Box
589
Active Menu: Functions and Dialog Boxes
591
ADCP Colour Span Function
592
Ping Average Function
594
TVG (Time Variable Gain) Functiontvg (Time Variable Gain) Function
595
Echogram Dialog Box
597
Beam Direction Function
598
New Layer Dialog Box
599
Layer Properties Dialog Box
604
Delete Layer Function
609
Bottom Detection Dialog Box
610
Single Target Detection Dialog Box
612
Information Pane Options Dialog Box
616
Combined View Settings
617
ADCP View Settings Dialog Box
618
ADCP Editing Dialog Box
618
Secondary Functions and Dialog Boxes
622
Replay File Dialog Box
622
Presentation Modes Dialog Box
625
Add Window Dialog Box
626
LAN Port Setup Dialog Box
627
Serial Port Setup Dialog Box
629
Port Monitor Dialog Box
631
Add Serial Port Dialog Box
633
Messages Dialog Box
634
Transducer Parameters Dialog Box
636
Pages in the Output Dialog Box
640
File Setup Page
640
I/O Setup Page
644
Processed Data to Output Page
648
Processed Data to File Page
652
Relay Output Page
657
Screen Recording Page
659
Pages in the Display Options Dialog Box
660
General Page
661
Tooltip Page
664
Pages in the Environment Dialog Box
665
Water Column Page
665
Transducer Face Page
668
Profile Page
669
Pages in the Advanced Sequencing Dialog Box
671
Ping Page
673
Ping Group Page
679
Ensemble Page
681
Sequence Page
682
Pages in the Installation Dialog Box
685
Transducer Installation Page
686
Transceiver Pages
693
Transceiver Installation Page
694
Transceiver IP Address Page
703
Sensor Installation Page
706
Sensor Configuration Page
711
Synchronization Page
714
Units Page
717
Trawl Page
719
Annotations Page
720
Remote Control Page
722
Remote Control: Application Information Page
724
Remote Control: as Server Page
725
Client Server Configuration Page
726
Web API Configuration Page
727
Software License Page
728
Pages in the Calibration Wizard
731
Calibration Wizard Dialog Box #1
731
Calibration Wizard Dialog Box #2
732
ADCP Calibration Pages
733
TS Calibration Pages
748
Pages in the Diagnostics Dialog Box
787
Processor Page
788
Sensors Page
790
Transceiver Page
792
Transducer Page
794
Noise Page
796
Ping Time Monitor Page
799
Pages in the Information Pane Options Dialog Box
801
Bottom Detection Dialog Box
801
Single Target Detection Dialog Box
804
Calculation Interval Dialog Box
808
Colour Scale Page
810
TS Histogram Page
812
Sv(F) Page
814
Ts(F) Page
815
ADCP Page
815
External Sensors Page
818
Pages in the Echogram Dialog Box
820
Lines Page
820
Echogram Page
823
Horizontal Axis Page
827
Pages in the ADCP View Settings Dialog Box
828
Horizontal Axis Page
829
Lines Page
830
View Selection Page
833
Concept Descriptions
836
Vessel Coordinate System
837
Vessel Coordinate System and Rotation Angles
839
About Ramping
840
Sound Speed Algorithms
841
Absorption Algorithm
842
Observation Range Versus Operational Frequency
843
About Bottom Echoes
845
About Sound Wave Propagation
846
What Is Sampling
847
Acoustic Noise
849
Contributing Factors
849
Self Noise
851
Ambient Noise
854
Fishing Gear Noise
854
Electrical Self Noise
854
Acoustic Doppler Current Profiler
856
ADCP Introduction
856
Doppler Shift
858
Depth Cells
859
Current Velocity
860
ADCP Data
861
Ping Average Using Sliding Average
863
Advertisement
Kongsberg Simrad EK80 Installation Manual (354 pages)
Brand:
Kongsberg
| Category:
Marine Equipment
| Size: 10.32 MB
Table of Contents
Table of Contents
5
About this Manual
13
Simrad Ek80
15
Important
16
System Description
17
System Diagram
19
Main System Units
21
Display Description
21
Processor Unit Description
22
Ethernet Switch Description
23
Transceiver Unit Description
23
Transducer Description
25
Simrad EC150-3C
25
Scope of Supply
27
Basic Items Provided with a Standard Delivery
27
Additional Required Items
29
Additional Optional Items
33
General Safety Rules
38
Installation Requirements
39
Supply Voltage Requirements
39
Uninterruptible Power Supply (UPS) Requirements
39
Cables and Wiring Requirements
40
Compass Deviation Requirements
40
Noise Sources
40
Dry Docking Requirements
41
Requirement for Classification Approval
41
Network Security
42
Support Information
43
Preparations
45
Installation Summary
46
About Installation Drawings
48
Tools, Equipment and Consumables Required for EK80 Installation
48
Personnel Qualifications
49
Where to Install the Transducer
50
Mount the Transducer Deep
50
Avoid Protruding Objects Near the Transducer
51
Mount the Transducer at Forward Part of Hull to Minimize the Effects from the Flow Boundary Water Layer
52
Keep the Transducer Far Away from the Propellers
53
Mount the Transducer at a Safe Distance from Bow Thruster(S)
53
Summary and General Recommendations
54
Acoustic Noise
56
Contributing Factors
56
Self Noise
58
Ambient Noise
60
Fishing Gear Noise
61
Electrical Self Noise
61
Some Means to Reduce Acoustic Noise
61
Vessel Coordinate System
63
Installing the Ek80 Hardware Units
66
Installing the Wide Band Transceiver (WBT) Using the Integrated Brackets
67
Installing the Wide Band Transceiver (WBT) in a 19" Rack
69
Installing the WBT Power Supply
71
Installing the Display
73
Installing a Commercial Computer
74
Installing the Enix Processor Unit
76
Installing the Ethernet Switch
78
Mounting the WBT Cabinet
80
Mounting the Drawers in the WBT Cabinet
83
Installing the Transducer(S)
85
Cable Layout and Interconnections
87
Read this First
88
Reducing Electrical Noise
88
Cable Plans
90
About the Cable Plans
90
Topside Cable Plan
91
Sonar Room Cable Plan with One Transceiver
92
Sonar Room Cable Plan with Two Transceivers
93
Sonar Room Cable Plan with WBT Cabinet
94
EC150-3C Cable Plan
95
List of EK80 Cables
96
Installing the EK80 Cables
99
Prerequisites for Cable Installation
99
Installing the EK80 Topside Cables
100
Installing the Wide Band Transceiver (WBT) Cables
102
Processor Unit Rear Connectors
104
Wide Band Transceiver (WBT) Connectors
106
Using a Steel Conduit to Protect the Transducer Cable
107
Splicing the Transducer Cable
109
Connections to Specific Hardware Items
112
KVM (Keyboard Video Mouse) Principle for a Remote Operating Position
112
Processor Unit Graphic Adapter
114
Processor Unit Serial Adapter
116
Serial Line Splitter Øverland UPC-3005
120
Serial Line Splitter Øverland UPC-5000P
124
Setting up the EK80 in a Synchronized System
128
About Synchronization
128
Synchronization Modes
129
Synchronization Sequences
130
Synchronization Using Clear to Send (CTS) and Request to Send (RTS) Signals
131
Synchronization Using the Auxiliary Socket on the Transceiver
131
Synchronizing the EK80 by Means of a Serial Port
133
Synchronizing the EK80 by Means of the Auxiliary Port
136
Cable Drawings and Specifications
138
AC Power Cable Using IEC C13 Inline Socket
139
Ground Cable
141
RS-232 Serial Line Connection Using Three Wires
142
RS-232 Serial Line Connection Using Five Wires
143
Serial Line Connection Using Five Wires
144
Used as Synchronization Trigger (Input or Output)
145
RS-485 Serial Line Connection Using Two or Four Wires
146
Moxa CP114EL-I Serial Line Adapter
147
RJ45 High Speed Ethernet Cable (1000Base-T)
149
Battery Power Cable
150
K-Sync Interface to Generic RS-232 Synchronization Input
150
Simrad TU40 Interface to Generic RS-232 Synchronization Input
153
Auxiliary Connector for Synchronization
155
Single Beam Low Power Transducer Connection to a Circular Transducer Socket
156
Split Beam Transducer Connection to an Amphenol Socket
158
Split Beam Transducer Connection for Single Beam Use on an Amphenol Socket
161
Burton Underwater Connectors on Split Beam Transducers for Deep Water
164
About Serial Lines
166
Basic Cable Requirements
169
Cable Trays
169
Radio Frequency Interference
170
Physical Protection of Cables
170
Grounding of System Cables
171
Cable Connections and Terminations
171
Cable Identification
172
Cable Glands and Termination Procedures
172
Dimensional Surveying
178
Quality Assurance of EK80 Data
179
Surveying the Transducer and the Navigation Sensors
181
Dimensional Survey Accuracy Requirements for ADCP Operations
183
Dimensional Survey Accuracy Requirements for Echo Sounding Operations
184
Vessel Coordinate System
184
Setting to Work
187
Setting to Work Summary
188
Making Sure that the EK80 Is Ready for Operational Use
190
Making Sure that the AC Mains Supply Voltage Is Correct
190
Making Sure that All EK80 Cables Are Properly Connected
191
Visual Inspection of the Display
192
Visual Inspection of the Processor Unit
194
Visual Inspection of the Wide Band Transceiver (WBT)
195
Visual Inspection of the WBT Cabinet
197
Visual Inspection of the EC150-3C Power Supply Unit
199
Turning on the EK80 for the First Time
201
Setting up Summary
201
Installing the EK80 Operational Software
203
Turning on the EK80 to Passive Mode
204
Obtaining and Installing the Software License
205
Defining the IP Address on the Processor Unit Network Adapter for Communication with the Transceiver
207
Installing One or more Transducers
208
Installing Transceiver Channels
212
Adjusting the Screen Resolution
214
Installing and Troubleshooting Network Time Protocol (NTP)
216
Installing Network Time Protocol (NTP)
216
Installing Network Time Protocol (NTP) Monitor
220
Troubleshooting the Network Time Protocol (NTP) Service
224
Configuring the EK80 for Normal Operation
226
Selecting Menu Language
226
Selecting Measurement Units
227
Defining the Raw Data Recording Parameters
227
Interfacing Peripheral Equipment
230
Installing Navigation Sensors and Other Sensors
230
Defining the Serial and Ethernet (LAN) Port Parameters
232
Setting up the Input from a Navigation System (GPS)
233
Configuring the Sensor Interface
236
Setting up a Serial or LAN (Ethernet) Port for Annotation Input
237
Connecting a Catch Monitoring System to a Serial or LAN (Ethernet) Port
239
Connecting a Trawl System to a Serial or LAN (Ethernet) Port
241
Setting up the Input from a Motion Reference Unit (MRU)
243
Setting up the Input from a Sound Speed Sensor
245
Setting up Depth Output to an External System
247
Exporting Sensor Data to a Peripheral System
249
Synchronizing the EK80 by Means of a Serial Port
251
Synchronizing the EK80 by Means of the Auxiliary Port
254
Setting up the Interface between the EK80 and the Simrad TD50
256
Test Procedures
258
Functional Test of the EK80 Wide Band Scientific Echo Sounder
259
Measuring Noise in Passive Operating Mode
261
Reading the Transceiver Hardware and Software Versions
263
Verifying the Communication with the Course Gyro
265
Verifying the Communication with a Navigation System (GPS)
267
Verifying the Communication with Speed Log
269
Verifying the Communication with the Motion Reference Unit (MRU)
271
Verifying the Communication with a Synchronization System
273
Making a Noise/Speed Curve to Determine Vessel Noise
275
Turning off the EK80
278
Installation Remarks
280
Technical Specifications
281
Introduction to Technical Specifications
282
Interface Specifications
283
Supported Datagram Formats for Annotation Data
283
Supported Datagram Formats for Distance Information
284
Supported Datagram Formats for Drop Keel Offset Information
284
Supported Datagram Formats for External Depth Input
285
Supported Datagram Formats for Position Information
285
Supported Datagram Formats for Heading and Gyro Information
286
Supported Datagram Formats for Trawl Information
286
Supported Datagram Formats for Motion Information
287
Supported Datagram Formats for Palette Control
288
Supported Datagram Formats for Catch Monitoring Information
288
Supported Datagram Formats for Sound Speed Sensors
289
Supported Datagram Formats for Speed Log Information
290
Supported Datagram Formats for Temperature Information
290
Supported Datagram Formats for Water Level Offset Information
291
Supported Formats for Processed Data to Output
291
Supported Formats for Processed Data to File
292
Power Requirements
294
Display Power Requirements
294
Processor Unit Power Requirements
294
Wide Band Transceiver (WBT) Power Requirements
295
WBT Power Supply Power Requirements
295
LBG408A-R2 Ethernet Switch Power Requirements
295
WBT Cabinet Power Requirements
296
Weights and Outline Dimensions
297
Display Weight and Outline Dimensions
297
Processor Unit Weight and Outline Dimensions
297
Wide Band Transceiver (WBT) Weight and Outline Dimensions
298
LBG408A-R2 Ethernet Switch Weight and Outline Dimensions
298
WBT Cabinet Weight and Outline Dimensions
299
Environmental Requirements
300
Display Environmental Requirements
300
Processor Unit Environmental Requirements
300
Wide Band Transceiver (WBT) Environmental Requirements
301
LBG408A-R2 Ethernet Switch Environmental Requirements
301
WBT Cabinet Environmental Requirements
301
Compass Safe Distance
303
Display Compass Safe Distance
303
Processor Unit Compass Safe Distance
303
Wide Band Transceiver (WBT) Compass Safe Distance
303
WBT Power Supply Compass Safe Distance
304
LBG408A-R2 Ethernet Switch Compass Safe Distance
304
WBT Cabinet Compass Safe Distance
304
Minimum Computer Requirements
305
Minimum Display Requirements
306
Drawing File
308
About the Drawings in the Drawing File
309
388697 Wide Band Transceiver (WBT) Outline Dimensions
310
385609 Processor Unit Dimensions
312
400930 WBT Cabinet Outline Dimensions
316
201575 Transducer Connector Assembly and Wiring
320
Equipment Handling
322
Transporting Kongsberg Maritime Equipment
323
Lifting Units and Transportation Boxes
324
Inspection of Units and Transportation Boxes after Arrival
325
Specifications for Storage Prior to Installation or Use
326
Unpacking Instructions
327
Unpacking Standard Parts and Units
328
Unpacking Mechanical Units
329
Unpacking Electronic and Electromechanical Units
330
Unpacking Transducers
331
Specifications for Storage after Unpacking
332
Kongsberg Simrad EK80 Instruction Manual (85 pages)
Wideband scientific echo sounder
Brand:
Kongsberg
| Category:
Marine Equipment
| Size: 4.11 MB
Table of Contents
Table of Contents
5
About this Manual
7
Introduction
9
Calibration for Target Strength (TS) Measurements
9
Support Information
11
Ts Calibration
12
Preparing TS Calibration
12
Selecting Normal Operation Parameters for TS Calibration
15
Recording Raw Data
16
Starting TS Calibration and Collecting Echo Data for Split-Beam Transducers
17
Starting TS Calibration and Collecting Echo Data for Single-Beam Transducers
20
Choosing Which Raw Data File(S) to Replay
23
Cleaning the Collected TS Data (Split-Beam Transducers)
24
Cleaning the Collected TS Data (Single-Beam Transducers)
25
Modifying, Adding and Removing a Frequency Band
26
Functions and Dialog Boxes
27
Calibration Wizard Dialog Box #1
27
Calibration Wizard Dialog Box #2 (Select Channel)
28
Calibration Wizard Dialog Box #3 (Select Sphere)
30
Calibration Wizard Dialog Box #1
33
Calibration Wizard Dialog Box #2 (Select Channel)
33
Calibration Wizard Dialog Box #3 (Select Sphere)
33
Calibration Wizard Dialog Box #4 (Import Data): Split-Beam Transducer
34
Calibration Wizard Dialog Box #4 (Import Data): Single-Beam Transducer
42
Calibration Wizard Dialog Box #5 (Process Data): Split-Beam Transducer
50
Calibration Wizard Dialog Box #5 (Process Data): Single-Beam Transducer
60
Replay File Dialog Box
70
Secondary Functions and Dialog Boxes
70
Edit/Add Sphere Dialog Box
72
Calibration Description Dialog Box
74
Calibration Wizard
74
How to Open
74
On the
74
To Open the then Select
74
New Calibration from Raw Data (Real Time or Replay)
75
Single Target Detection Dialog Box
75
This Opens Page 2 in the Wizard
75
Advertisement
Kongsberg Simrad EK80 Instruction Manual (44 pages)
Wideband scientific echo sounder
Brand:
Kongsberg
| Category:
Marine Equipment
| Size: 13.59 MB
Table of Contents
Table of Contents
4
About this Manual
6
Introduction
8
About Acoustic Doppler Current Profiler (ADCP) Calibration
8
Vessel Coordinate System and Rotation Angles
9
ADCP Calibration Summary
10
Support Information
11
Calibrating the Adcp System
12
Preparing Circle Calibration
12
Circle Calibration for ADCP in Real Time
15
Circle Calibration for ADCP in Replay
19
Reprocessing Calibration Results for ADCP
21
Functions and Dialog Boxes
23
Calibration Function
23
Calibration Wizard Dialog Box #1
24
Calibration Wizard Dialog Box #2
25
Calibration Wizard Dialog Box #2 Reprocess
26
Options in the Calibration Wizard
27
Calibration Wizard Dialog Box #3 Real Time
28
Calibration Wizard Dialog Box #3 Replay
36
Kongsberg Simrad EK80 Quick Start Manual (15 pages)
Brand:
Kongsberg
| Category:
Marine Equipment
| Size: 0.42 MB
Table of Contents
Table of Contents
3
1 Introduction
4
Personnel and Location
4
Test Equipment
4
2 HAT Procedure EK80
5
Hardware and Software Registration
5
Visual Inspection
5
Test Procedure
5
Check Installation
5
Configuration of Interfaces
5
Dimensional Survey
6
Functional Test of Echosounders
6
Functional Test of ADCP
7
Noise Measurements
8
Data Download
9
3 List of Items
10
4 Check List
12
5 Customer Acceptance Form
15
Kongsberg Simrad EK80 Quick Start Manual (3 pages)
Brand:
Kongsberg
| Category:
Marine Equipment
| Size: 0.19 MB
Advertisement
Related Products
Kongsberg EM - REV M
Kongsberg EN 250 - DATASHEET REV C
Kongsberg EM series
Kongsberg EM 712
Kongsberg EA 400
Kongsberg EM 2000
Kongsberg EM 1002
Kongsberg EM 710
Kongsberg EM 122
Kongsberg EM 950
Kongsberg Categories
Marine Equipment
Sonar
Marine Radio
Transceiver
Radio
More Kongsberg Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL