Advertisement

Junction box
A
Cable gland
B
Terminal block
C
Cable
D
Cable screen (Do not connect
E
the cable screen to vessel
ground.)
The junction box may be
F
connected to vessel ground.
Procedure
1
Mount the junction box in a
suitable location.
2
Terminate the steel conduit
containing the transducer cable
to the junction box housing, or
as close to the junction box as
possible.
3
Feed the cables through the cable glands.
4
Remove the insulation from the transducer cable. Connect the individual wires
to the terminal block.
5
Remove the insulation from the extension cable. Connect the individual wires
to the terminal block.
6
Make sure that you have connected the wires 1:1, and that the colours match.
7
Connect the screens from both cables together.
8
Make sure that the cable screens do not have any electrical connection to the
junction box housing or the cable gland.
If necessary, insulate the screens.
Related topics