12.3

Signals and wiring

• Be sure to use the load side encoder cables specified in this section. Using products other than those
specified may cause a malfunction.
• Contact the manufacturer of the load-side encoder being used for information on specifications,
performance, and guarantees.

Encoder cable configuration diagram

Configuration diagrams of the servo amplifier and load-side encoder are shown below. The cable to be used differs depending
on the load-side encoder.
Encoder cable configuration diagram for linear encoders
For encoder cables for linear encoders, refer to the following manual.
MR-J5 Partner's Encoder User's Manual
The encoder cable to be used differs depending on the load-side encoder.
■Servo amplifier without CN2L
MR-J4FCCBL03M branch cable
Servo amplifier
CN2
CN2
■Servo amplifier with CN2L
A linear encoder can be connected without using an MR-J4FCCBL03M branch cable. In addition, a four-wire type linear
encoder can also be used.
Servo amplifier
CN2
CN2L
12 USING A FULLY CLOSED LOOP SYSTEM
452
12.3 Signals and wiring
MOTOR
Encoder of rotary servo motor
SCALE
Encoder cable
Encoder of rotary servo motor
Encoder cable
Linear encoder
Linear encoder
Load-side
encoder
Load-side
encoder