Mitsubishi Electric MELSERVO-J5 User Manual page 66

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

Connecting wires
■Fabricating the wire insulator
Refer to the following for the stripped length of the wire insulator. Set the appropriate length based on the wire type and
fabrication condition.
Page 61 Connector
Insulator
Stripped length
Twist the core wires lightly and straighten them as follows.
Loose and bent strands
A ferrule can also be used when connecting to the connectors. If using a ferrule, choose from one of the ferrules and the
crimping tools shown below.
Servo amplifier
MR-J5-10_ to
MR-J5-100_
MR-J5W2-_G_
MR-J5W3-_G_
MR-J5-200_ to
MR-J5-350_
MR-J5-500_
MR-J5-700_
MR-J5-60_4_ to
MR-J5-350_4_
■Inserting wire
Insert only one wire or ferrule into each wire insertion hole on each power connector.
Insert the open tool as follows and push it down to open the spring.
While the open tool is pushed down, insert the stripped wire into the wire insertion hole. Check the wire insertion depth so that
the wire insulator is not caught by the spring and that the conductive part of the stripped wire is not exposed.
Release the open tool to fix the wire. Pull the wire lightly to confirm that the wire is surely connected. In addition, confirm that
the ends of the core wires do not stick out of the connector.
3 SIGNALS AND WIRING
64
3.3 Explanation of power supply system
Core
Twist and straighten the strands.
Wire size
AWG 16
AWG 14
AWG 16
AWG 14
AWG 12
AWG 10
AWG 8
AWG 16
AWG 14
(1) Push down the open tool.
(3) Release the open tool to fix the wire.
(2) Insert the wire.
Ferrule model (Phoenix Contact)
For one wire
For two wires
AI 1,5 -10 BK
AI-TWIN 2X 1,5 -10 BK
AI 2,5 -10 BU
AI 1,5 -10 BK
AI-TWIN 2X 1,5 -10 BK
AI 2,5 -10 BU
AI-TWIN 2X 2,5 -10 BU
AI 4 -10 GY
Al6-12 YE
Al10-12 RD
AI 1,5 -10 BK
AI-TWIN 2X 1,5 -10 BK
AI 2,5 -10 BU
Crimping tool (Phoenix
Contact)
CRIMPFOX-ZA3
CRIMPFOX-25R
CRIMPFOX-ZA3

Advertisement