Connection example
■For 3-phase 200 V AC to 240 V AC power supply
3-phase
200 V AC to 240 V AC
*1 When a surge protector is used.
■For 1-phase 200 V AC to 240 V AC power supply
*1
1-phase
200 V AC to 240 V AC
*1 Connect the power supply to L1 and L3. Leave L2 open.
*2 When a surge protector is used.
■For 3-phase 380 V AC to 480 V AC power supply
3-phase
380 V AC to 480 V AC
*1 When a surge protector is used.
6 OPTIONS AND PERIPHERAL EQUIPMENT
254
6.16 EMC filter (recommended)
EMC filter
MCCB
1
2
3
Surge protector
1
2
3
EMC filter
MCCB
1
2
3
Surge protector
1
2
3
EMC filter
MCCB
1
2
3
Surge protector
1
2
3
Servo amplifier
MC
4
5
6
L11
*1
Servo amplifier
MC
4
5
6
*2
Servo amplifier
MC
4
5
6
*1
L1
L2
L3
L21
L1
L2
L3
L11
L21
L1
L2
L3
L11
L21