Mitsubishi Electric MELSERVO-J5 User Manual page 84

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

Output device explanation [G] [WG]
■MBR (Electromagnetic brake interlock)
MBR is off in the servo-off state or at an alarm occurrence.
If using the device, set an operation delay time of the electromagnetic brake in [Pr. PC02].
For details. refer to "Electromagnetic brake interlock function" in the following manual.
MR-J5 User's Manual (Function)
■VLC (Limiting speed)
If the speed reaches the speed limit value in the torque mode, VLC will turn on. VLC will turn off in the servo-off state.
The device cannot be used in the position mode or the velocity mode.
■ZSP (Zero speed detection)
If the servo motor speed is the zero speed or less, ZSP will turn on. The zero speed can be changed with [Pr. PC07]. The
following shows an example when the initial value (50) is set in [Pr. PC07].
OFF level
70 r/min
ON level
50 r/min
Servo motor
0 r/min
speed
ON level
-50 r/min
OFF level
-70 r/min
ON
ZSP
(Zero speed detection)
OFF
ZSP will turn on when the servo motor speed is reduced to 50 r/min (at (1)), and will turn off when the servo motor is increased
to 70 r/min again (at (2)).
ZSP will turn on when the servo motor is decelerated again to 50 r/min (at (3)), and will turn off when the servo motor speed
reaches -70 r/min (at (4)).
The range from the point when the servo motor speed has reached the on-level and ZSP turns on, to the point when the
speed has increased again and reached the off-level is called a hysteresis width.
The hysteresis width is 20 r/min for this servo amplifier.
If using a linear servo motor, replace [r/min] with [mm/s].
■TLC (Limiting torque)
If the torque reaches the torque limit value when torque is generated, TLC will turn on. TLC will turn off in the servo-off state.
In the torque mode, TLC is off.
■DOA (General-purpose output A)/DOB (General-purpose output B)/DOC (General-purpose
output C)
The pins to which the device is assigned can be switched on/off with the object "Digital outputs". For details, refer to "[Digital
outputs (Obj. 60FEh)]" in the User's Manual (Object Dictionary). The output device is available on servo amplifiers with
firmware version B6 or later.
3 SIGNALS AND WIRING
82
3.5 Signal (device) explanation
(1)
(3)
(2)
(4)
20 r/min
(Hysteresis width)
[Pr. PC07]
[Pr. PC07]
20 r/min
(Hysteresis width)

Advertisement

Table of Contents
loading

Table of Contents