Mitsubishi Electric MELSERVO-J5 User Manual page 31

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

Precautions
• When closely mounting multiple servo amplifiers, the servo amplifier on the right must have a larger depth than that on the
left. Otherwise, the CNP1, CNP2, and CNP3 connectors cannot be removed.
• Refer to the following table for availability of close mounting.
Servo amplifier
MR-J5-10_ to MR-J5-70_
MR-J5-100_ to MR-J5-200_
MR-J5-350_ to MR-J5-700_
MR-J5W2-22G_ to MR-J5W2-1010G_
MR-J5W3-222G_ to MR-J5W3-444G_
MR-J5-60_4_ to MR-J5-350_4_
When 3-phase power supply is input
Possible
Possible
Possible
Impossible
When 1-phase power supply is input
Possible
Impossible
2 INSTALLATION
2.1 Mounting direction and clearances
2
29

Advertisement

Table of Contents
loading

Table of Contents