4-d mounting hole
(Varnish is removed only from bottom right (face and back side))
P P1
W1
W ± 2
Servo amplifier
Power factor
improving
DC reactor
MR-J5-200_
FR-HEL-3.7K
MR-J5-350_
FR-HEL-7.5K
MR-J5-500_
FR-HEL-11K
MR-J5-700_
FR-HEL-15K
*1 Use this for grounding.
*2 When using the power factor improving DC reactor, remove the short-circuit bar between P3 and P4.
*3 Maximum dimensions. The dimensions vary depending on the curvature of the input/output lines.
*4 Selection requirements for the wire size are as follows.
Wire type: 600 V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction requirements: Single wire set in midair
6 OPTIONS AND PERIPHERAL EQUIPMENT
232
6.11 Power factor improving DC reactor
D or less
D3
D2
D1
Dimensions [mm]
W
W1
H
D
77
55
92
82
86
60
113
98
105
64
133
112
105
64
133
115
*1
FR-HEL
P1
*2
P
*3
D1
D2
D3
66
57
37
81
72
43
92
79
47
97
84
48.5
Servo amplifier
P3
P4
5 m or less
Terminal
Mass
size
[kg]
d
M4
M4
1.5
M4
M5
2.5
M6
M6
3.3
M6
M6
4.1
2
Wire [mm
]
*4
2 (AWG 14)
3.5 (AWG 12)
5.5 (AWG 10)
8 (AWG 8)

Advertisement