Mitsubishi Electric MELSERVO-J5 User Manual page 259

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

■Surge protector (recommended)
• To use an EMC filter on the servo amplifier, a surge protector is required.
To prevent damage due to surges (such as lightning and sparks) applied to the AC power supply lines, connect the following
surge protectors to the main circuit power supply (L1/L2/L3).
Surge protector
Maximum
model
continuous
operating
voltage
50/60 Hz
RSPD-250-U4
3 AC 250 V
RSPD-500-U4
3 AC 500 V
LT-CS32G801WS
3 AC 275 V
• RSPD series (Okaya Electric Industries)
[Unit: mm]
φ4.2 ± 0.5
Resin
Lead
1
2
3
Case
41 ± 1
• LT-CS-WS series (Soshin Electric)
Operation
status display
19
Vinyl wire
38
DC operating
Voltage
start voltage
protection
level
700 V ± 25 %
1300 V
1300 V ± 25 %
2000 V
660 V ± 10 %
1400 V
Grounding wire
22.5
Nominal
Maximum
discharge
discharge
current 8/20
current 8/20
μs
μs
2500 A
5000 A
2500 A
5000 A
5000 A
8000 A
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.16 EMC filter (recommended)
Impulse current
Manufacturer
life
8/20 μs - 1000 A
About 300 times
Okaya Electric
Industries Co.,
Ltd.
About 300 times
Okaya Electric
Industries Co.,
Ltd.
About 1000 times
Soshin Electric
Co., Ltd.
6
257

Advertisement

Table of Contents
loading

Table of Contents