Mitsubishi Electric MELSERVO-J5 User Manual page 195

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

Environment
Item
Operation
Ambient temperature
0 ˚C to 60 ˚C (non-freezing)
Class 3K3 (IEC 60721-3-3)
Ambient humidity
5 %RH to 95 %RH (non-condensing)
Ambience
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust
Altitude/atmospheric
Altitude: 2000 m or less
pressure
Vibration resistance
When there is continuous vibration:
10 Hz to 57 Hz, displacement amplitude
0.075 mm
57 Hz to 150 Hz, acceleration amplitude
2
9.8 m/s
Class 3M1 (IEC 60721-3-3)
When there is continuous vibration:
10 Hz to 55 Hz, acceleration amplitude 5.9
2
m/s
Transportation
-25 ˚C to 70 ˚C (non-freezing)
Class 2K12 (IEC 60721-3-2)
5 %RH to 95 %RH (non-condensing)
Transportation conditions: Must be
transported by ground/sea, or air at an
atmospheric pressure of 700 hPa or more.
2 Hz to 8 Hz, displacement amplitude (half
amplitude) 7.5 mm
8 Hz to 200 Hz, acceleration amplitude 20
2
m/s
Class 2M3 (IEC 60721-3-2)
6 OPTIONS AND PERIPHERAL EQUIPMENT
Storage
-25 ˚C to 70 ˚C (non-freezing)
Class 1K4 (IEC 60721-3-1)
5 %RH to 95 %RH (non-condensing)
Atmospheric pressure: 700 hPa to 1060
hPa
(equivalent to the altitude of -400 m to
3000 m.)
2 Hz to 9 Hz, displacement amplitude (half
amplitude) 1.5 mm
9 Hz to 200 Hz, acceleration amplitude 5
2
m/s
Class 1M2 (IEC 60721-3-1)
6.3 MR-CM simple converter