Torque control mode
■Sink I/O interface
Forced stop 2
Speed selection 1
Speed selection 2
Forward rotation selection
Reverse rotation selection
Upper limit setting
Analog torque command
+8 V/maximum torque
Upper limit setting
Analog speed limit 0 V to
±10 V/rated speed
*7
MR Configurator2
+
*1 To prevent an electric shock, connect the protective earth (PE) terminal (the terminal marked with the
to the protective earth (PE) of the cabinet.
*2 Connect the diode in the correct direction. If it is connected reversely, the servo amplifier may malfunction and not output signals,
disabling protective circuits such as EM2 (Forced stop 2).
*3 Install a forced stop switch (normally closed contact).
*4 Supply 24 V DC ± 10 % to interfaces from outside. The total current capacity of these power supplies is 500 mA maximum. The
amperage will not exceed 500 mA when all I/O signals are used. Reducing the number of I/O points decreases the current capacity. For
the amperage required for interfaces, refer to the following.
Page 96 Digital input interface DI-1
Although the diagram shows the input signal and the output signal each using a separate 24 V DC power supply for illustrative purposes,
the system can be configured to use a single 24 V DC power supply.
*5 If no alarm is occurring, ALM (Malfunction) is on (normally closed contact).
*6 The pins with the same signal name are connected in the servo amplifier.
*7 Use SW1DNC-MRC2-_.
*8 If not using the STO function, attach the short-circuit connector that came with the servo amplifier.
*9 To prevent an unexpected restart of the servo amplifier, configure a circuit that turns off EM2 when the main circuit power supply is
turned off.
*10 For source interfaces, the positive and negative outputs of the power supply are reversed as compared with sink interfaces.
3 SIGNALS AND WIRING
52
3.2 Example I/O signal connections
10 m or less
Main circuit power supply
*3
Servo-on
Reset
*4
24 V DC
2 m or less
Personal
computer
USB cable
(option)
Personal
computer
Ethernet cable
*8
Short-circuit connector
(Packed with the servo amplifier)
Servo amplifier
*6
*6
*9
CN3
CN3
EM2
42
46
DOCOM
SON
15
47
DOCOM
RES
19
SP1
41
48
ALM
SP2
16
23
ZSP
RS1
18
RS2
17
25
VLC
DICOM
20
49
RD
DICOM
21
*6
CN3
P15R
1
8
LZ
TC
27
9
LZR
LG
28
4
LA
5
LAR
VLA
2
6
LB
7
LBR
Plate
SD
34
LG
33
OP
Plate
SD
CN6
3
MO1
CN5
1
LG
2
MO2
2 m or less
CN1
CN8
*1
10 m or less
*4
24 V DC
*2
*5
Malfunction
RA1
Zero speed detection
RA2
Limiting speed
RA3
Ready
RA4
Encoder Z-phase pulse
(differential line driver)
Encoder A-phase pulse
(differential line driver)
Encoder B-phase pulse
(differential line driver)
Control common
Encoder Z-phase pulse (open collector)
2 m or less
Analog monitor 1
± 10 V DC
± 10 V DC
Analog monitor 2
symbol) of the servo amplifier