Chapter 5 Signals And Wiring - Mitsubishi Electric -MR-CV User Manual

Power regeneration converter unit
Table of Contents

Advertisement

5
SIGNALS AND WIRING
Precautions
• Insulate the conductive parts of the terminals.
• Turn off the power and wait for 20 minutes or more until the charge light of the unit turns off. Checking the voltage between
L+ and L- using the tester, etc. is recommended.
• To prevent failure and malfunction, only the power supply/signal specified in the user's manual should be connected to a
corresponding terminal.
• To prevent unexpected operation of the servo motor, wire the equipment correctly and securely.
• Make sure to connect the cables and connectors by using the fixing screws and the locking mechanism. Failing to do so
may cause the cables and connectors to disconnect during operation.
• Unless stated otherwise, all connection diagrams in this user's manual are sink interface diagrams.
• Install a surge absorbing diode in the correct direction. Failing to do so may cause the amplifier to malfunction and not to
output signals, disabling protective circuits such as the emergency stop.
Converter unit
24 V DC
DOCOM
Control output
signal
For sink output interface
• If the wires are not properly secured to the terminal block, the poor contact may cause the wires and terminal block to
generate heat. Be sure to secure the wires with the specified torque.
• Check that no operation signal is being input to the drive unit and servo amplifier before resetting an alarm or releasing the
emergency stop. Failing to do so may cause an unexpected operation.
• If the power supply is shut off by a molded-case circuit breaker or a fuse, remove the cause and secure safety before
switching the power on.
• Install the converter unit according to the EMC guidelines because electromagnetic interference may affect the electronic
equipment used near the converter unit.
• To prevent an electric shock or a fire, do not disassemble, repair, or modify the product. Disassembled, repaired, and/or
modified products are not covered under warranty.
• Eliminate static electricity before performing actions such as wiring or operating a switch.
Converter unit
DOCOM
Control output
RA
signal
For source output interface
24 V DC
RA
5 SIGNALS AND WIRING
5
31