Ps7Dw-20V14B-F Junction Terminal Block (Recommended) [G] - Mitsubishi Electric MELSERVO-J5 User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5:
Table of Contents

Advertisement

6.5
PS7DW-20V14B-F junction terminal block
(recommended) [G]
Usage
Use the junction terminal block (PS7DW-20V14B-F) with the option cable (MR-J2HBUS_M) as a set. A connection example is
shown below.
Servo amplifier
Cable clamp
(AERSBAN-ESET)
CN3
MR-J2HBUS_M
For MR-J2HBUS_M, ground the option cable on the junction terminal block side with the cable clamp fitting (AERSBAN-
ESET). For the use of the cable clamp fitting, refer to the following.
Page 244 Cable clamp fitting AERSBAN-_SET
Connection of MR-J2HBUS_M cable and junction terminal block
Servo amplifier
CN3
*2
TPR2
1
1
LSP
2
2
DOCOM
3
3
MO1
4
4
DICOM
5
5
LA
6
6
LB
7
7
LZ
8
8
INP
9
9
*2
TPR1
10
10
LG
11
11
LSN
12
12
MBR
13
13
MO2
14
14
ALM
15
15
LAR
16
16
LBR
17
17
LZR
18
18
DOG
19
19
EM2
20
20
SD
Shell
Shell
*1 Numbers in "_" indicate the cable length.
05: 0.5 m
1: 1 m
5: 5 m
*2 This signal can be used only on the MR-J5-_G_-RJ_.
6 OPTIONS AND PERIPHERAL EQUIPMENT
210

6.5 PS7DW-20V14B-F junction terminal block (recommended) [G]

Junction terminal block
PS7DW-20V14B-F
*1
MR-J2HBUS_M
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
Shell
Shell
Connector: 52316-2019 (Molex)
Shell kit: 52370-2070 (Molex)
Junction terminal block
PS7DW-20V14B-F
Terminal block
1
TPR2
2
LSP
3
DOCOM
4
MO1
5
DICOM
6
LA
7
LB
8
LZ
9
INP
10
TPR1
11
LG
12
LSN
13
MBR
14
MO2
15
ALM
16
LAR
17
LBR
18
LZR
19
DOG
20
EM2
E
SD
*2
*2

Advertisement

Table of Contents
loading

Table of Contents