TE02: Simulation of Compile Cycles (only HMI
Advanced)
14.1
Brief description
14.1.1
Function
If, at the SINUMERIK user interface "HMI Advanced" part programs are simulated that use
compile cycles, depending on the compile cycle being used, general specific conditions must
be established. These are described in the subsequent chapters.
14.2
OEM transformations
When using OEM transformations, the simulation runtime environment has to be set.
Proceed as follows
1. On the computer, on which HMI Advanced is installed, in addition to the directory available
as standard "<
Advanced installation path >/OEM".
2. In the "OEM" directory, create the file "DPSIM.TEA" with the following content:
$MN_NC_USER_CODE_CONF_NAME_TAB[196]="TRAORI"
$MN_NC_USER_CODE_CONF_NAME_TAB[197]="_TRAORI"
$MN_NC_USER_CODE_CONF_NAME_TAB[198]="TRACON"
$MN_NC_USER_CODE_CONF_NAME_TAB[199]="_TRACON"
CHANDATA(1)
$MC_AXCONF_GEOAX_ASSIGN_TAB[0]=1
$MC_AXCONF_GEOAX_ASSIGN_TAB[1]=2
$MC_AXCONF_GEOAX_ASSIGN_TAB[2]=3
$MC_TRAFO_RESET_VALUE=0
; Make sure that transformation types 4096 - 4101 are deleted
$MC_TRAFO_TYPE_1=0
$MC_TRAFO_TYPE_2=0
$MC_TRAFO_TYPE_3=0
; Delete transformation chains with OEM transformations
$MC_TRACON_CHAIN_1[0]=0
$MC_TRACON_CHAIN_1[1]=0
; NOTICE! No spaces after M30
M30
3. In the "OEM" directory, create the file "DPSIM.INI" with the following content:
[PRELOAD]
CYCLES=1
CYCLEINTERFACE=0
Special functions
Function Manual, 01/2015, 6FC5397-2BP40-5BA2
HMI Advanced installation path >/MMC2", create a new directory "< HMI
14
561